Centre for the Evaluation of Vaccination (CEV), Vaccine & Infectious Disease Institute (VAXINFECTIO), Faculty of Medicine and Health Sciences, University of Antwerp, Belgium.
Centre for the Evaluation of Vaccination (CEV), Vaccine & Infectious Disease Institute (VAXINFECTIO), Faculty of Medicine and Health Sciences, University of Antwerp, Belgium.
J Virol Methods. 2019 Feb;264:23-30. doi: 10.1016/j.jviromet.2018.11.008. Epub 2018 Nov 16.
Great interest has been directed towards the use of first-void (FV) urine as a liquid biopsy for high-risk HPV DNA testing. The aim of this study was to investigate the potential effect of a first generation FV urine collection device on the detection of HPV DNA and to assess if the concentration of HPV DNA varies between FV urine collected in the morning and those collected later during the day. In this prospective cohort study, 33 self-reported HPV-positive women participated. An FV urine sample was collected by these women in the morning (first urine of the day) and another sample was collected later that day for four consecutive days using two different collection methods; i.e., the Colli-Pee and a standard urine cup. Samples were collected at home and returned at ambient temperature to the laboratory by postal mail. HPV DNA testing was conducted with the Riatol qPCR HPV genotyping assay. Based on the combined generalized linear mixed model used, there was no significant impact of the timing of collection (morning versus later during the day) on copies of HPV DNA, whereas Colli-Pee collected samples show higher HPV concentrations than cup collected samples. However, at high concentrations of hDNA, the benefit of the Colli-Pee disappeared.
人们对使用首次尿(FV)作为高危型 HPV DNA 检测的液体活检非常感兴趣。本研究旨在探讨第一代 FV 尿液收集装置对 HPV DNA 检测的潜在影响,并评估在一天中不同时间收集的 FV 尿液中 HPV DNA 的浓度是否存在差异。在这项前瞻性队列研究中,33 名自述 HPV 阳性的女性参与了研究。这些女性在早上(当天的第一次尿液)收集了一份 FV 尿液样本,并在接下来的四天中使用两种不同的收集方法(即 Colli-Pee 和标准尿杯)分别收集了另一份样本。样本在家中采集,并在常温下通过邮寄方式返回实验室。HPV DNA 检测采用 Riatol qPCR HPV 基因分型检测法进行。基于使用的组合广义线性混合模型,收集时间(早上与当天晚些时候)对 HPV DNA 拷贝数没有显著影响,而 Colli-Pee 收集的样本显示出比杯收集样本更高的 HPV 浓度。然而,在 hDNA 浓度较高时,Colli-Pee 的优势消失了。