• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Quantum efficiency measurement of an x-ray charge-coupled device by means of an x-ray generator monochromatized over the 0.2-1.2  keV spectral region.

作者信息

Hubert Sébastien, Boubault Franck

出版信息

Appl Opt. 2018 Oct 1;57(28):8228-8235. doi: 10.1364/AO.57.008228.

DOI:10.1364/AO.57.008228
PMID:30461772
Abstract

The Atomic Energy Commission has been developing an x-ray calibration laboratory for several years close to the Laser MégaJoule Facility mainly to calibrate x-ray cameras. Based on x-ray generators, great effort is being carried out to obtain x-ray monochromatic sources over the 0.1-10 keV spectral range. Moreover, their routine availability is a prerequisite while getting reduced uncertainties. To achieve this purpose, two x-ray monochromators have been recently developed, the former running below 1.5 keV and the latter in the harder x-ray region. The work presented in this paper constitutes, to the best of our knowledge, the first radiometric calibration of an x-ray camera, namely, a charge-coupled device (CCD). The CCD is thin and back illuminated with a 1300×1340 pixel, 20  ×20   area. It has been calibrated by means of our soft x-ray monochromator based on Rowland circle geometry. This apparatus is able to take on board simultaneously two detectors under vacuum: the CCD to be calibrated and a silicon drift spectrometer (SDD), which acts as a reference detector to obtain the x-ray monochromatic intensity. An internal specific vacuum manipulator allows putting successively each detector in front of the scanning exit slit. Quantum efficiency (QE) of the CCD has thus been measured over the 0.2-1.2 keV region, due to the reference SDD. The latter was previously calibrated on the same monochromator by cross-calibration with another SDD calibrated at the Physikalisch-Technische Bundesanstalt (PTB) Radiometry Laboratory, on the synchrotron radiation facility BESSY. QE measurements are then compared to the CCD manufacturer's model and with previous ones performed on the same camera by means of our hard x-ray monochromator (2-10 keV). Comparison of these results with further PTB efficiency calibration of the reference SDD used to calibrate the CCD is discussed and allows concluding definitively about the validity of measurements performed by our x-ray monochromators.

摘要

相似文献

1
Quantum efficiency measurement of an x-ray charge-coupled device by means of an x-ray generator monochromatized over the 0.2-1.2  keV spectral region.
Appl Opt. 2018 Oct 1;57(28):8228-8235. doi: 10.1364/AO.57.008228.
2
Absolute calibration of the spectral sensitivity of an x-ray streak camera over the 0.1-10 keV spectral range equipped with CsI photocathode.
Rev Sci Instrum. 2023 Nov 1;94(11). doi: 10.1063/5.0156102.
3
Quantum efficiency measurements of an x-ray charge-coupled device in the 2-10  keV spectral region by means of a double crystal monochromator coupled to an x-ray tube.
Appl Opt. 2014 Dec 1;53(34):8078-85. doi: 10.1364/AO.53.008078.
4
Reference-free total reflection X-ray fluorescence analysis of semiconductor surfaces with synchrotron radiation.利用同步辐射对半导体表面进行无参比全反射X射线荧光分析。
Anal Chem. 2007 Oct 15;79(20):7873-82. doi: 10.1021/ac071236p. Epub 2007 Sep 20.
5
Absolute x-ray calibration of a gated x-ray framing camera for the Laser MegaJoule facility in the 0.1 keV-1 keV spectral range.
Rev Sci Instrum. 2021 Mar 1;92(3):035101. doi: 10.1063/5.0004105.
6
Absolute radiant power measurement for the Au M lines of laser-plasma using a calibrated broadband soft X-ray spectrometer with flat-spectral response.使用具有平坦光谱响应的校准宽带软X射线光谱仪对激光等离子体的金M线进行绝对辐射功率测量。
Rev Sci Instrum. 2014 Jan;85(1):013503. doi: 10.1063/1.4846915.
7
The x-ray calibration facility of the laser integration line in the 0.9-10 keV range: the high energy x-ray source and some applications.0.9 - 10千电子伏特范围内激光集成线的X射线校准设施:高能X射线源及一些应用
Rev Sci Instrum. 2010 May;81(5):053501. doi: 10.1063/1.3427236.
8
Characterization of a charge-coupled-device detector in the 1100-0.14-nm (1-eV to 9-keV) spectral region.
Appl Opt. 1999 Jan 1;38(1):29-36. doi: 10.1364/ao.38.000029.
9
Relative detection efficiency of back- and front-illuminated charge-coupled device cameras for X-rays between 1 keV and 18 keV.背照式和前照式电荷耦合器件相机对1keV至18keV X射线的相对探测效率。
Rev Sci Instrum. 2007 Sep;78(9):093102. doi: 10.1063/1.2779214.
10
High-accuracy detector calibration in the 3-1500 eV spectral range at the PTB radiometry laboratory.在德国物理技术研究院(PTB)辐射测量实验室进行的3 - 1500电子伏特光谱范围内的高精度探测器校准。
J Synchrotron Radiat. 1998 May 1;5(Pt 3):866-8. doi: 10.1107/S0909049597014076.