Absolute x-ray calibration of a gated x-ray framing camera for the Laser MegaJoule facility in the 0.1 keV-1 keV spectral range.

作者信息

Hubert S, Boubault F

机构信息

CEA-CESTA, F33116 Le Barp, France.

出版信息

Rev Sci Instrum. 2021 Mar 1;92(3):035101. doi: 10.1063/5.0004105.

DOI:10.1063/5.0004105
PMID:33820028
Abstract

X-ray framing cameras (XRFCs) are routinely used at the Laser MegaJoule facility in x-ray imaging plasma diagnostics around the target chamber. Most of these diagnostics are based on multilayer x-ray toroidal mirrors under grazing incidence. The absolute calibration of the XRFCs is expressly expected both to optimize the signal-to-noise ratio for the dynamic range for specific experiments and to quantitatively process the data. The purpose of this paper is to describe our technique to routinely calibrate these instruments in the sub-keV spectral range. The calibration presented in this work was carried out using the XRFC enclosed in a sealed "airbox" structure. This calibration relies on a Manson source recently upgraded to operate at high emission current (5 mA) with 10 kV accelerating voltage to work with a 1-m grazing-incidence Rowland circle monochromator. The framing camera sensitivity was absolutely determined over the 0.1-1.2 spectral range with an average uncertainty of 2.4% rms while operating in DC mode. Finally, we compare the results with a synchrotron source calibration previously obtained and a theoretical model.

摘要

相似文献

1
Absolute x-ray calibration of a gated x-ray framing camera for the Laser MegaJoule facility in the 0.1 keV-1 keV spectral range.
Rev Sci Instrum. 2021 Mar 1;92(3):035101. doi: 10.1063/5.0004105.
2
Absolute calibration of the spectral sensitivity of an x-ray streak camera over the 0.1-10 keV spectral range equipped with CsI photocathode.
Rev Sci Instrum. 2023 Nov 1;94(11). doi: 10.1063/5.0156102.
3
X-ray intensity, stability, and source size characterizations for the 10 kV/5 mA water cooled upgraded Manson source at the Atomic Energy Commission for Laser MégaJoule Facility.激光兆焦耳装置原子能委员会10 kV/5 mA水冷升级曼森源的X射线强度、稳定性及源尺寸特性
Rev Sci Instrum. 2019 Nov 1;90(11):115110. doi: 10.1063/1.5125746.
4
Quantum efficiency measurement of an x-ray charge-coupled device by means of an x-ray generator monochromatized over the 0.2-1.2  keV spectral region.
Appl Opt. 2018 Oct 1;57(28):8228-8235. doi: 10.1364/AO.57.008228.
5
The x-ray calibration facility of the laser integration line in the 0.9-10 keV range: the high energy x-ray source and some applications.0.9 - 10千电子伏特范围内激光集成线的X射线校准设施:高能X射线源及一些应用
Rev Sci Instrum. 2010 May;81(5):053501. doi: 10.1063/1.3427236.
6
X-ray imaging with grazing-incidence microscopes developed for the LIL program.为激光惯性约束聚变(LIL)项目研发的掠入射显微镜进行的X射线成像。
Rev Sci Instrum. 2007 Mar;78(3):033704. doi: 10.1063/1.2715865.
7
First set of gated x-ray imaging diagnostics for the Laser Megajoule facility.激光兆焦耳装置的首批门控X射线成像诊断设备
Rev Sci Instrum. 2016 Mar;87(3):033706. doi: 10.1063/1.4942930.
8
Quantum efficiency measurements of an x-ray charge-coupled device in the 2-10  keV spectral region by means of a double crystal monochromator coupled to an x-ray tube.
Appl Opt. 2014 Dec 1;53(34):8078-85. doi: 10.1364/AO.53.008078.
9
X-ray diagnostic calibration with the tabletop laser facility EQUINOX.使用桌面激光设备EQUINOX进行X射线诊断校准。
Rev Sci Instrum. 2008 Oct;79(10):10E932. doi: 10.1063/1.2965212.
10
Progress toward absolute calibrations of DC x-ray sources from 1 keV to >30 keV for Z diagnostics applications.用于Z诊断应用的直流X射线源从1keV到>30keV的绝对校准进展。
Rev Sci Instrum. 2024 Aug 1;95(8). doi: 10.1063/5.0213745.