Suppr超能文献

Clinical application of quantitative coronary angiography using the CAAS system: preliminary results of the INTACT study (International Nifedipine Trial on Antiatherosclerotic Therapy).

作者信息

Jost S, Deckers J W, Nellessen U, Rafflenbeul W, Hecker H, Reiber J H, Hugenholtz P G, Lichtlen P R

机构信息

Medizinische Hochschule, Abteilung für Kardiologie, Hannover, BRD.

出版信息

Int J Card Imaging. 1988;3(2-3):75-86. doi: 10.1007/BF01814880.

Abstract

It is the objective of the INTACT-study to test in man, whether a significant retardation of the progression of coronary artery disease is attainable with the Ca-antagonist nifedipine; this may be possible on the basis of numerous animal experiments. INTACT is a prospective, randomized, double blind, placebo controlled investigation in 423 patients with preferably early stages of coronary sclerosis in whom a progression of the disease seems likely. A proper coronary angiogram led to inclusion of the patients in the study (October 1983-June 1985). Over the following 3-years-period patients received either nifedipine 80 mg/day or placebo. The study is concluded by a control coronary angiogram with angiographic projections which are identical to those of the first coronary angiography. The extent of coronary sclerosis is objectivated by computer-assisted quantitative measurement of the entire coronary arterial system with the CAAS-system (Rotterdam). For definition purposes the coronary artery system subdivided into 25 segments. Parameters for progression assessment will be mean segment diameter, minimal obstruction diameter, percentage severity of obstruction, length of obstruction and plaque area. So far 4826 coronary segments have been analyzed from the first angiograms of 383 patients. Per patient an average of 12.6 different segments could be evaluated in at least one angiographic projection. The major coronary segments could be measured in 72-93% of the patients in one or more angiographic projections (at the average about 2 different projections). Five hundred and forty-six coronary obstructions were analyzed; 131 of these were total occlusions. Only 9% of the length of the vessel contours detected by the computer algorithm required manual correction by the operators, suggesting a high reliability of the system. It can be concluded that quantitative measurement of the complete coronary artery system can indeed be obtained in a large angiographical multicenter study such as INTACT.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验