Suppr超能文献

可穿戴传感器能否为计时起立行走测试增添有意义的信息?一项针对肥胖女性的研究。

Do wearable sensors add meaningful information to the Timed Up and Go test? A study on obese women.

作者信息

Cimolin Veronica, Cau Nicola, Malchiodi Albedi Giovanna, Aspesi Valentina, Merenda Vanessa, Galli Manuela, Capodaglio Paolo

机构信息

Department of Electronics, Information and Bioengineering, Politecnico di Milano, p.za Leonardo da Vinci 32, 20133 Milan, Italy.

Department of Electronics, Information and Bioengineering, Politecnico di Milano, p.za Leonardo da Vinci 32, 20133 Milan, Italy; Rehabilitation Unit and Research Lab in Biomechanics and Rehabilitation, S Giuseppe Hospital, Istituto Auxologico Italiano, Piancavallo, VB, Italy.

出版信息

J Electromyogr Kinesiol. 2019 Feb;44:78-85. doi: 10.1016/j.jelekin.2018.12.001. Epub 2018 Dec 5.

Abstract

The purpose of this study was to validate Time Up and Go test (TUG) as measured by a single Inertial Measurement Unit (IMU) placed on the lower back to that measured by a stopwatch in obese and normal weight women; in addition, the comparison of the performance of TUG test between obese and healthy women using the instrumented TUG (iTUG). Forty-four severely obese women and 14 age-matched healthy women were assessed simultaneously by IMU and stopwatch. The comparison between manual and instrumented assessment of total time duration showed no significant differences both in the healthy (8.32 ± 0.96 s vs. 8.52 ± 0.97 s, p > 0.05) and in the obese group (9.99 ± 2.28 s vs. 9.81 ± 2.52 s; p > 0.05). The comparison between obese and healthy group exhibited significant differences in terms of total time duration both during manual and iTUG, which is longer in obese women than normal weight women. The duration of the sub-phases in obese group is longer with the exception of sit-to-stand and stand-to-sit phase, with lower turning velocity both in mid- and final turning sub-phase. The results suggest that the iTUG is an objective and fast mobility test and it could add useful information to the manual TUG for clinical practice.

摘要

本研究的目的是验证通过置于下背部的单个惯性测量单元(IMU)测量的起立行走测试(TUG)与秒表测量的结果在肥胖和正常体重女性中的一致性;此外,使用仪器化起立行走测试(iTUG)比较肥胖女性和健康女性的TUG测试表现。44名重度肥胖女性和14名年龄匹配的健康女性同时接受了IMU和秒表评估。手动评估和仪器化评估的总时长比较显示,健康组(8.32±0.96秒对8.52±0.97秒,p>0.05)和肥胖组(9.99±2.28秒对9.81±2.52秒;p>0.05)均无显著差异。肥胖组和健康组之间在手动和iTUG测试的总时长方面均存在显著差异,肥胖女性的总时长比正常体重女性更长。肥胖组除坐立和站立坐下阶段外,各子阶段的时长更长,在中间和最终转身子阶段的转身速度更低。结果表明,iTUG是一种客观且快速的运动能力测试,可为临床实践中的手动TUG测试提供有用信息。