Radiology Unit, Department of Diagnostic Medicine and Prevention, S. Orsola Hospital, University of Bologna, Bologna, Italy.
Department of Medical and Surgical Sciences, Sant'Orsola Hospital, University of Bologna, Bologna, Italy.
Clin Radiol. 2019 Mar;74(3):220-227. doi: 10.1016/j.crad.2018.11.005. Epub 2018 Dec 13.
To identify, in vitro, the best fruit juice to use as oral contrast agent in magnetic resonance cholangiopancreatography (MRCP) and to test, in vivo, the best natural juice and the new parameters in MRCP sequences identified in vitro.
The in vitro evaluations consisted of measuring the T2 values of a pure solution of manganese (Mn) and iron (Fe) at different concentrations, measuring the content of Mn and Fe in five commercial juices and their T2 relaxation times, and identifying the optimal juice dilution for suppressing the gastrointestinal fluid signal. The new parameters of MRCP sequences were tested in vivo.
Manganese alone strongly influenced the shortening of the T2 values (p=0.004). The T2 value with an echo time (TE) of ≥1,000 ms enabled sufficient intestinal fluid suppression in the case of high juice dilution. A flip angle of 90° maximised the differences between the high signal from static fluids, such as the bile and the fluid in the gastrointestinal tract, using fast imaging employing steady-state acquisition (FIESTA) sequences (p<0.001).
The shortening of the T2 relaxation time depended only on the Mn concentration. All the commercial juices had an Mn concentration sufficient to suppress the gastrointestinal fluid signal using long TE sequences. The oral ingestion of commercial juice before MRCP was enough to suppress the signal from the gastrointestinal fluids, regardless of its dilution after ingestion. When using FIESTA sequences, a flip angle of 90° allowed the best suppression of gastrointestinal fluid signals.
在体外鉴定用于磁共振胰胆管成像(MRCP)的最佳果汁作为口服对比剂,并在体内测试最佳天然果汁和体外鉴定的新 MRCP 序列参数。
体外评估包括测量不同浓度的纯锰(Mn)和铁(Fe)溶液的 T2 值,测量五种商业果汁及其 T2 弛豫时间中的 Mn 和 Fe 含量,并确定抑制胃肠道液体信号的最佳果汁稀释度。新的 MRCP 序列参数在体内进行测试。
单独的 Mn 强烈影响 T2 值的缩短(p=0.004)。在高果汁稀释的情况下,TE 为≥1000ms 的 T2 值可以充分抑制肠道液体信号。使用快速成像采用稳态采集(FIESTA)序列时,90°的翻转角可以最大限度地提高静态液体(如胆汁和胃肠道中的液体)的高信号之间的差异(p<0.001)。
T2 弛豫时间的缩短仅取决于 Mn 浓度。所有商业果汁都具有足够的 Mn 浓度,可使用长 TE 序列抑制胃肠道液体信号。在 MRCP 之前口服商业果汁足以抑制胃肠道液体的信号,而无需考虑其摄入后的稀释度。使用 FIESTA 序列时,90°的翻转角允许最佳抑制胃肠道液体信号。