Suppr超能文献

利用眼底摄影评估婴儿型内斜视客观眼扭转的可靠性

Reliability of objective ocular torsion assessment using fundus photography in infantile esotropia.

作者信息

Khanna R K, Pasco J, Santallier M, Pisella P-J, Arsene S

机构信息

Ophthalmology Department, CHRU Bretonneau, University Hospital, 2, boulevard Tonnellé, 37044 Tours, France.

Medical Information Department, CHRU Bretonneau, University Hospital, 2, boulevard Tonnellé, 37044 Tours, France.

出版信息

J Fr Ophtalmol. 2019 Jan;42(1):16-21. doi: 10.1016/j.jfo.2018.04.016. Epub 2018 Dec 15.

Abstract

PURPOSE

To evaluate the interobserver reproducibility of objective ocular torsion measurements in infantile esotropia using fundus photography analysis.

MATERIALS AND METHODS

This retrospective observational study was conducted in our ophthalmology department at the University Hospital in Tours from 2009 to 2015.

OBJECTIVE

Ocular torsion was assessed using fundus photography and analysed on Adobe Photoshop software within a population of children with infantile esotropia. Two observers, an orthoptist and an ophthalmologist, carried out the evaluation separately. The interobserver agreement was calculated for quantitative measurement by the interclass correlation coefficient (ICC) and by Cohen's Kappa coefficient for qualitative assessment.

RESULTS

A total of 200 eyes (100 subjects, mean age: 6.88 years) were assessed. Statistical analyses for quantitative measurements resulted in an ICC of 0.98 (95% CI, 0.97-0.99) for right eyes, 0.96 (95% CI, 0.95-0.97) for left eyes, 0.98 (CI 95%, 0.97-0.98) for pre- operative eyes and 0.96 (95% CI, 0.95-0.97) for postoperative eyes. The ICC calculated on all four hundred fundus photographs was 0.97 (95% CI, 0.97-0.98). The interobserver agreement for qualitative measurements resulted in a Kappa coefficient of 0.91 for right eyes, 0.85 for left eyes, 0.90 for preoperative eyes and 0.86 for postoperative eyes. The analysis of all four hundred eyes returned a Kappa coefficient of 0.88.

CONCLUSIONS

Objective ocular torsion assessment using our procedure, whether by an orthoptist or ophthalmologist, is a reliable and reproducible method for the management of infantile esotropia.

摘要

目的

使用眼底摄影分析评估婴儿型内斜视中客观眼扭转测量的观察者间可重复性。

材料与方法

这项回顾性观察研究于2009年至2015年在图尔大学医院眼科进行。

目的

在婴儿型内斜视儿童群体中,使用眼底摄影评估眼扭转,并在Adobe Photoshop软件上进行分析。两名观察者,一名斜视矫正师和一名眼科医生,分别进行评估。通过组内相关系数(ICC)计算观察者间定量测量的一致性,并通过Cohen's Kappa系数进行定性评估。

结果

共评估了200只眼(100名受试者,平均年龄:6.88岁)。定量测量的统计分析结果显示,右眼的ICC为0.98(95%可信区间,0.97 - 0.99),左眼为0.96(95%可信区间,0.95 - 0.97),术前眼为0.98(95%可信区间,0.97 - 0.98),术后眼为0.96(95%可信区间,0.95 - 0.97)。在所有四百张眼底照片上计算的ICC为0.97(95%可信区间,0.97 - 0.98)。定性测量的观察者间一致性结果显示,右眼的Kappa系数为0.91,左眼为0.85,术前眼为0.90,术后眼为0.86。对所有四百只眼的分析得出Kappa系数为0.88。

结论

使用我们的方法进行客观眼扭转评估,无论是由斜视矫正师还是眼科医生进行,都是一种用于管理婴儿型内斜视的可靠且可重复的方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验