Abstract

Optical coherence tomography (OCT), enables high-resolution 3D imaging of the morphology of light scattering tissues. From the OCT signal, parameters can be extracted and related to tissue structures. One of the quantitative parameters is the attenuation coefficient; the rate at which the intensity of detected light decays in depth. To couple the quantitative parameters with the histology one-to-one registration is needed. The primary aim of this study is to validate a registration method of quantitative OCT parameters to histological tissue outcome through one-to-one registration of OCT with histology. We matched OCT images of unstained fixated prostate tissue slices with corresponding histology slides, wherein different histologic types were demarcated. Attenuation coefficients were determined by a supervised automated exponential fit (corrected for point spread function and sensitivity roll-off related signal losses) over a depth of 0.32 mm starting from 0.10 mm below the automatically detected tissue edge. Finally, the attenuation coefficients corresponding to the different tissue types of the prostate were compared. From the attenuation coefficients, we produced the squared relative residue and goodness-of-fit metric R . This article explains the method to perform supervised automated quantitative analysis of OCT data, and the one-to-one registration of OCT extracted quantitative data with histopathological outcomes.

摘要

光学相干断层扫描(OCT)能够对光散射组织的形态进行高分辨率的 3D 成像。从 OCT 信号中,可以提取出参数,并与组织结构相关联。定量参数之一是衰减系数,即探测光在深度上衰减的速率。为了将定量参数与组织学一一对应,需要进行配准。本研究的主要目的是通过 OCT 与组织学的一一配准,验证将 OCT 定量参数与组织学结果进行配准的方法。我们将未经染色固定的前列腺组织切片的 OCT 图像与相应的组织学载玻片进行匹配,其中不同的组织学类型被划定。衰减系数通过在从自动检测到的组织边缘下方 0.10 毫米开始的 0.32 毫米深度上,通过对受点扩散函数和灵敏度滚降相关信号损失校正的指数拟合进行确定。最后,比较了与前列腺不同组织类型相对应的衰减系数。从衰减系数中,我们生成了平方相对残差和拟合优度度量 R。本文解释了对 OCT 数据进行监督自动定量分析的方法,以及 OCT 提取的定量数据与组织病理学结果的一一配准。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验