Vascular Imaging Lab, Department of Radiology, University of Washington, 850, Republican Street, Box 358050, Seattle, WA, 98019, USA.
Healthcare Department, Philips Research China, Shanghai, China.
MAGMA. 2019 Jun;32(3):343-357. doi: 10.1007/s10334-018-0730-8. Epub 2019 Jan 3.
To develop a 3D multi-contrast IVW protocol with 0.5-mm isotropic resolution and a scan time of 5 min per sequence.
Pre-contrast T1w VISTA, DANTE prepared PDw VISTA, SNAP, and post-contrast T1w VISTA were accelerated using cartesian undersampling with target ordering method (CUSTOM) and self-supporting tailored k-space estimation for parallel imaging reconstruction (STEP). CUSTOM + STEP IVW was compared to full-sample IVW, SENSE-accelerated IVW, and CUSTOM + zero-filled Fourier reconstruction in normal volunteers and subjects with intracranial atherosclerotic disease (ICAD). Image quality, vessel delineation, CSF suppression, and blood suppression were compared.
CUSTOM + STEP vessel wall delineation was comparable to full-sample IVW and better than SENSE IVW for vessel wall delineation on T1w VISTA and luminal contrast on SNAP. Average image quality and wall depiction were significantly improved using STEP reconstruction compared with zero-filled Fourier reconstruction, with no significant difference in CSF or blood suppression.
CUSTOM + STEP allowed multi-contrast 3D 0.5-mm isotropic IVW within 30 min. Although some quantitative and qualitative scores for CUSTOM - STEP were lower than fully sampled IVW, CUSTOM + STEP provided comparable vessel wall delineation as full-sample IVW and was superior to SENSE. CUSTOM + STEP IVW was well tolerated by patients and showed good delineation of ICAD plaque.
开发一种具有 0.5 毫米各向同性分辨率和 5 分钟/序列扫描时间的 3D 多对比度 IVW 方案。
使用笛卡尔欠采样与目标排序法(CUSTOM)和自支撑定制傅里叶空间估计并行成像重建(STEP)对对比前 T1w VISTA、DANTE 准备 PDw VISTA、SNAP 和对比后 T1w VISTA 进行加速。在正常志愿者和颅内动脉粥样硬化性疾病(ICAD)患者中,将 CUSTOM+STEP IVW 与全采样 IVW、SENSE 加速 IVW 和 CUSTOM+零填充傅里叶重建进行比较。比较图像质量、血管勾画、CSF 抑制和血液抑制。
CUSTOM+STEP 血管壁勾画在 T1w VISTA 上的血管壁勾画和 SNAP 上的管腔对比度方面与全采样 IVW 相当,优于 SENSE IVW。与零填充傅里叶重建相比,STEP 重建显著提高了平均图像质量和壁描绘,CSF 或血液抑制无显著差异。
CUSTOM+STEP 允许在 30 分钟内进行多对比度 3D 0.5 毫米各向同性 IVW。尽管 CUSTOM+STEP 的一些定量和定性评分低于全采样 IVW,但 CUSTOM+STEP 提供了与全采样 IVW 相当的血管壁勾画,优于 SENSE。CUSTOM+STEP IVW 患者耐受性良好,可清晰显示 ICAD 斑块。