Abstract

OBJECTIVE

To evaluate the efficacy of different sonic and ultrasonic devices in the elimination of debris from canal irregularities in artificial root canals.

MATERIALS AND METHODS

A resin model of a transparent radicular canal filled with dentin debris was used. Five groups were tested, namely: Group 1 - ultrasonic insert 15.02; Group 2 - ultrasonic insert 25/25 IRRI K; Group 3 - ultrasonic insert 25/25 IRRI S; Group 4 - sonic insert 20/28 Eddy on a vibrating sonic air-scaler handpiece; Group 5 - 20.02 K-file inserted on a Safety M4 handpiece. Two different irrigants (5% sodium hypochlorite and 17% EDTA) and 3 different times of activation (20, 40, and 60 seconds) were tested. Means and standard deviations were calculated and statistically analyzed with the Kruskal-Wallis and Wilcoxon tests (p<0.05).

RESULTS

No statistically significant differences were found between the two irrigants used. Group 4 removed more debris than the other groups (p<0.05). Groups 1, 2, and 3 removed more debris than group 5 (p<0.05). A statistically significant difference (p<0.05) was found for the time of activation in all groups and at all canal levels, except between 40 and 60 seconds in group 4 at coronal and middle third level (p>0.05).

CONCLUSIONS

No significant differences were found between 5% sodium hypochlorite and 17% EDTA. When the time of activation rises, the dentin debris removal increases in all groups. Both sonic and ultrasonic activation demonstrate high capacity for dentin debris removal.

摘要

目的

评估不同声波和超声设备在清除人工根管不规则处的牙本质碎片方面的疗效。

材料和方法

使用填充有牙本质碎片的透明根管树脂模型进行测试。共分为 5 组,分别为:第 1 组-超声插入器 15.02;第 2 组-超声插入器 25/25 IRRI K;第 3 组-超声插入器 25/25 IRRI S;第 4 组-置于振动超声空气锉手机上的声能插入器 20/28 Eddy;第 5 组-置于 Safety M4 手机上的 20.02 K 锉。测试了两种不同的冲洗剂(5%次氯酸钠和 17% EDTA)和三种不同的激活时间(20、40 和 60 秒)。计算平均值和标准差,并采用 Kruskal-Wallis 和 Wilcoxon 检验进行统计学分析(p<0.05)。

结果

使用的两种冲洗剂之间没有发现统计学差异。第 4 组比其他组去除更多的牙本质碎片(p<0.05)。第 1、2 和 3 组比第 5 组去除更多的牙本质碎片(p<0.05)。除第 4 组在冠部和中部三分之一水平的 40 秒和 60 秒之间外(p>0.05),所有组和所有根管水平的激活时间均存在统计学差异(p<0.05)。

结论

5%次氯酸钠和 17% EDTA 之间没有发现显著差异。随着激活时间的增加,所有组的牙本质碎片去除量都增加。声波和超声激活均显示出较高的牙本质碎片去除能力。