Computed tomography urography with iterative reconstruction algorithm in congenital urinary tract abnormalities in children - association of radiation dose with image quality.

作者信息

Bombiński Przemysław, Brzewski Michał, Warchoł Stanisław, Biejat Agnieszka, Banasiuk Marcin, Gołębiowski Marek

机构信息

Department of Paediatric Radiology, Medical University of Warsaw, Poland.

Department of Paediatric Surgery and Urology, Medical University of Warsaw, Poland.

出版信息

Pol J Radiol. 2018 Apr 27;83:e175-e182. doi: 10.5114/pjr.2018.75808. eCollection 2018.

Abstract

PURPOSE

To assess the extent to which a radiation dose can be lowered without compromising image quality and diagnostic confidence in congenital urinary tract abnormalities in children by using a CT scanner with an iterative reconstruction algorithm.

MATERIAL AND METHODS

120 CT urography image series were analysed retrospectively. Image series were divided into four study groups depending on effective radiation dose (group 1: 0.8-2 mSv; group 2: 2-4 mSv; group 3: 4-6 mSv; group 4: 6-11 mSv). Objective and subjective image quality were investigated. In objective analysis, measurements of attenuation and standard deviation (SD) in five regions of interest (ROIs) were performed in 109 excretory image series, and image noise was evaluated. In subjective analysis, two independent radiologists evaluated 138 kidney units for subjective image quality and diagnostic confidence.

RESULTS

There were no significant differences in image noise in objective evaluation between the following study groups: 2 vs. 3 and 3 vs. 4 in all ROIs (with the only exception in spleen SD measurement between study groups 2 vs. 3), while there was significantly more image noise in group 2 in comparison to group 4. For all other ROIs in all study groups, there was more image noise on lower dose images. There were no significant differences in pairwise comparisons between study groups in subjective image quality. Diagnostic confidence was not significantly different between all study groups.

CONCLUSIONS

Low-dose CT urography can be a valuable method in congenital urinary tract abnormalities in children. Despite poorer image quality, diagnostic confidence is not significantly compromised in examinations performed with lower radiation doses.

摘要

目的

通过使用具有迭代重建算法的CT扫描仪,评估在不影响儿童先天性尿路异常的图像质量和诊断可信度的情况下,辐射剂量能够降低的程度。

材料与方法

回顾性分析120例CT尿路造影图像系列。根据有效辐射剂量将图像系列分为四个研究组(第1组:0.8 - 2 mSv;第2组:2 - 4 mSv;第3组:4 - 6 mSv;第4组:6 - 11 mSv)。研究客观和主观图像质量。在客观分析中,对109例排泄期图像系列在五个感兴趣区域(ROI)进行衰减和标准差(SD)测量,并评估图像噪声。在主观分析中,两名独立的放射科医生对138个肾单位的主观图像质量和诊断可信度进行评估。

结果

在所有感兴趣区域中,以下研究组之间在客观评估中的图像噪声无显著差异:第2组与第3组以及第3组与第4组(唯一的例外是第2组与第3组之间脾脏SD测量),而与第4组相比,第2组的图像噪声明显更多。在所有研究组的所有其他感兴趣区域中,较低剂量图像的图像噪声更多。研究组之间在主观图像质量的两两比较中无显著差异。所有研究组之间的诊断可信度无显著差异。

结论

低剂量CT尿路造影可成为儿童先天性尿路异常的一种有价值的方法。尽管图像质量较差,但在较低辐射剂量下进行的检查中,诊断可信度并未受到显著影响。