Abstract

Rapid and reliable identification of microorganisms in the clinical laboratory is essential for an early and accurate diagnosis guiding timely therapy. However, conventional methods are sometimes unreliable and show controversial outcomes. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been reported as a rapid and reliable method for identification of bacteria and fungi isolated from clinical samples. Members of the genus Raoultella are increasingly recognized as clinically relevant. There are difficulties in their identification at the species level since sequencing the 16S rRNA or the rpoB genes does not show conclusive results. The aim of this study has been to compare two MALDI-TOF MS systems (Vitek MS and Bruker Biotyper) with Vitek2 and API20E systems for differentiation of Raoultella species. A collection of 97 clinical isolates of Raoultella species was identified with Vitek MS, in parallel with Vitek2 and API, and finally with Bruker Biotyper. Among the two most widely used MALDI-TOF MS platforms, results obtained with Vitek MS were slightly superior to those obtained with the Bruker Biotyper system, with sensitivities and specificities of 98.9/57.9% and 98.8/37.0%, respectively. The current commercial phenotypic identification systems are not optimized for the identification of Raoultella species. Our results indicate that MALDI-TOF-based identification is more accurate and sensitive than that provided by phenotypic methods.

摘要

快速、准确地鉴定临床实验室中的微生物对于早期、准确的诊断指导及时治疗至关重要。然而,传统方法有时不可靠,结果存在争议。基质辅助激光解吸电离飞行时间质谱(MALDI-TOF MS)已被报道为一种快速、可靠的方法,可用于鉴定从临床样本中分离出的细菌和真菌。鲁氏菌属的成员越来越被认为与临床相关。在种水平上对其进行鉴定存在困难,因为测序 16S rRNA 或 rpoB 基因并不能得出明确的结果。本研究的目的是比较两种 MALDI-TOF MS 系统(Vitek MS 和 Bruker Biotyper)与 Vitek2 和 API20E 系统在区分鲁氏菌属物种方面的性能。用 Vitek MS 与 Vitek2 和 API 平行鉴定了 97 株临床分离的鲁氏菌属,最后用 Bruker Biotyper 鉴定。在两种应用最广泛的 MALDI-TOF MS 平台中,Vitek MS 获得的结果略优于 Bruker Biotyper 系统,其灵敏度和特异性分别为 98.9%/57.9%和 98.8%/37.0%。当前的商业表型鉴定系统并未针对鲁氏菌属的鉴定进行优化。我们的结果表明,基于 MALDI-TOF 的鉴定比表型方法更准确、更敏感。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验