无人值守与有人值守血压测量。

Unattended Versus Attended Blood Pressure Measurement.

机构信息

From the Department of Clinical and Experimental Sciences, University of Brescia, 2a Medicina ASST Spedali Civili di Brescia, Italy.

出版信息

Hypertension. 2019 Mar;73(3):736-742. doi: 10.1161/HYPERTENSIONAHA.118.12187.

Abstract

It has been suggested that measurement of unattended or automated oscillatory blood pressure (BP) values may provide advantages over conventional BP measurement. Some international guidelines now suggest automated oscillatory BP as the preferred approach for measuring BP. Data on the relationship between automated oscillatory BP and cardiovascular events are much less solid as compared to those obtained with the standard approach; preliminary data suggested that automated oscillatory BP might be more strictly correlated with organ damage. The aim of our study was to evaluate the relationship between attended or unattended BP and organ damage in 564 subjects undergoing an echocardiogram and carotid ultrasound at an European Society of Hypertension Excellence Center.Both unattended BP (patient alone in the room, an oscillometric device programmed to perform 3 BP measurements, at 1-minute intervals, after 5 minutes) and attended BP were measured with the same device, on the same day of the ultrasonographic examination, in random order. In 564 patients (age 61±15 years, 41% female 78% hypertensives) systolic unattended BP was lower as compared with attended BP (128.0±15.5 versus 134.5±19.9 mm Hg). Left ventricular mass index was similarly correlated with attended and unattended systolic BP ( r=0.205 and r=0.194, respectively). Carotid intima-media thickness was also significantly correlated with both attended and unattended systolic BP (mean max intima-media thickness: r=0.206 and r=0.194, respectively, P<0.0001). The differences between correlations were not statistically significant. Our results suggest that attended and unattended BP values are similarly related with hypertensive organ damage.

摘要

有人提出,测量无人值守或自动化的振荡血压(BP)值可能比传统的 BP 测量具有优势。一些国际指南现在建议将自动化振荡 BP 作为测量 BP 的首选方法。与使用标准方法获得的数据相比,关于自动化振荡 BP 与心血管事件之间的关系的数据要少得多;初步数据表明,自动化振荡 BP 可能与器官损伤的相关性更严格。我们的研究目的是评估在一个欧洲高血压卓越中心,564 名接受超声心动图和颈动脉超声检查的患者中,有或无人值守的 BP 与器官损伤之间的关系。无人值守的 BP(患者独自在房间里,一台血压计设备设定为在 5 分钟后每隔 1 分钟进行 3 次血压测量)和有人值守的 BP 都是在同一天,使用相同的设备,以随机顺序测量的。在 564 名患者(年龄 61±15 岁,41%为女性,78%为高血压患者)中,无人值守的收缩压低于有人值守的收缩压(128.0±15.5 与 134.5±19.9mmHg)。左心室质量指数与有人值守和无人值守的收缩压也呈相似的相关性(r=0.205 和 r=0.194)。颈动脉内膜中层厚度与有人值守和无人值守的收缩压也呈显著相关(平均最大内膜中层厚度:r=0.206 和 r=0.194,均<0.0001)。相关性之间的差异无统计学意义。我们的结果表明,有人值守和无人值守的 BP 值与高血压器官损伤的相关性相似。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验