Abstract

PURPOSE

To compare surface properties of 2 brands of pre-polymerized resin blocks for complete dentures (CAD/CAM PMMA) to conventional heat-polymerized PMMA.

MATERIALS AND METHODS

A total of 45 rectangular specimens (25 × 25 × 3 mm) were fabricated from 3 brands of PMMA (n = 15/group): AvaDent CAD/CAM PMMA, Tizian-Schütz CAD/CAM PMMA, Meliodent conventional PMMA. Specimens were examined for wettability using the sessile drop method, surface roughness using a digital contact profilometer, and microhardness using Vickers hardness number. Statistical analysis was performed using one-way ANOVA and Tukey pairwise multiple comparisons. p-Values of ≤0.05 were considered significant.

RESULTS

AvaDent specimens demonstrated the highest mean contact angle (72.87 ± 48°) and the highest mean Vickers hardness number (20.62 ± 0.33). The conventional heat-polymerized specimens showed the highest mean surface roughness (0.22 ± 0.071 μm). Tizian-Schütz specimens showed the lowest mean surface roughness (0.12 ± 0.02 μm).

CONCLUSIONS

As CAD/CAM PMMA groups exhibited significantly more favorable surface properties in comparison to the conventional heat-polymerized groups, CAD/CAM dentures are expected to be more durable. Different brands of CAD/CAM PMMA may have inherent variations in surface properties.

摘要

目的

比较 2 种品牌的预聚物树脂牙(CAD/CAM PMMA)和传统热聚合 PMMA 牙的表面性能。

材料与方法

共制作了 3 种品牌的 PMMA(n = 15 /组)的 45 个矩形样本(25 × 25 × 3mm):AvaDent CAD/CAM PMMA、Tizian-Schütz CAD/CAM PMMA、Meliodent 传统 PMMA。使用悬滴法评估润湿性,使用数字接触式轮廓仪评估表面粗糙度,使用维氏硬度计评估显微硬度。使用单向方差分析和 Tukey 多重比较进行统计分析。p 值≤0.05 被认为具有统计学意义。

结果

AvaDent 样本的平均接触角最大(72.87 ± 48°),平均维氏硬度值最高(20.62 ± 0.33)。传统热聚合样本的平均表面粗糙度最高(0.22 ± 0.071μm)。Tizian-Schütz 样本的平均表面粗糙度最低(0.12 ± 0.02μm)。

结论

与传统热聚合组相比,CAD/CAM PMMA 组表现出明显更优的表面性能,预计 CAD/CAM 义齿更耐用。不同品牌的 CAD/CAM PMMA 可能具有固有表面性能的差异。