Suppr超能文献

超声引导下的肛门外括约肌肌电图检查。

Ultrasound-Guided Needle Electromyography of the External Anal Sphincter.

机构信息

Department of Rehabilitation Medicine, Graduate School, The Catholic University of Korea, Seoul, Republic of Korea.

Department of Rehabilitation Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul 06591, Republic of Korea.

出版信息

PM R. 2019 Jul;11(7):731-736. doi: 10.1002/pmrj.12012. Epub 2019 Feb 8.

Abstract

BACKGROUND

Anal sphincter needle electromyography (EMG) is a useful tool to evaluate various neurologic lesions. However, landmark-based needle placement has risks of missing the intended target including risk of bowel penetration. Ultrasound guidance has been widely used to enhance needle placement for various interventional procedures, but it has not been previously reported for use in anal sphincter EMG.

OBJECTIVE

To demonstrate the accuracy of ultrasound-guided needle insertion into the external anal sphincter (EAS).

DESIGN

Observational study.

SETTING

Tertiary care university hospital.

PARTICIPANTS

A single live male participant and six fresh cadavers.

METHODS

A preliminary study was conducted in a single live male participant to investigate the utility of ultrasonography imaging for the EAS and proper transducer location. After this preliminary study, 12 sides of the EAS in six fresh cadavers were assessed. A hooked fine wire was inserted into the EAS under ultrasound guidance.

MAIN OUTCOME MEASURES

Accuracy of needle placement was assessed after cadaver dissection.

RESULTS

The EAS was easily identified with ultrasound in preliminary and cadaver studies. The needle tips were located in the EAS in 11 of 12 cadavers.

CONCLUSIONS

Ultrasound-guided needle EMG of the EAS is convenient and accurate in cadavers and may be useful in clinical practice. Further studies comparing ultrasound-guided and landmark-guided needle EMG of the EAS in live patients will be needed.

摘要

背景

肛门括约肌针肌电图(EMG)是评估各种神经病变的有用工具。然而,基于标志的针放置具有错过目标的风险,包括肠道穿透的风险。超声引导已广泛用于增强各种介入性操作的针放置,但以前没有报道用于肛门括约肌 EMG。

目的

证明超声引导下插入外肛门括约肌(EAS)的准确性。

设计

观察性研究。

设置

三级保健大学医院。

参与者

一名单一的男性活体参与者和六名新鲜尸体。

方法

在一名单一的男性活体参与者中进行了初步研究,以调查超声成像在外肛门括约肌(EAS)和适当的换能器位置的实用性。在这项初步研究之后,评估了六个新鲜尸体的 12 侧 EAS。在超声引导下将弯钩细金属丝插入 EAS。

主要观察指标

尸体解剖后评估针放置的准确性。

结果

在初步和尸体研究中,EAS 很容易通过超声识别。在 12 具尸体中有 11 具尸体的针尖位于 EAS 中。

结论

超声引导的 EAS 针 EMG 在尸体中方便且准确,在临床实践中可能有用。需要进一步研究比较超声引导和基于标志的 EAS 针 EMG 在活体患者中的应用。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验