Suppr超能文献

白内障手术中各中心位置关系分析

Analysis of Positional Relationships of Various Centers in Cataract Surgery.

作者信息

Song Woo Keun, Lee Jin Ah, Kim Jae Yong, Kim Myoung Joon, Tchah Hungwon

机构信息

Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.

出版信息

Korean J Ophthalmol. 2019 Feb;33(1):70-81. doi: 10.3341/kjo.2018.0085.

Abstract

PURPOSE

To analyze the positional relationships of various centers in patients undergoing femtosecond laser-assisted cataract surgery (FLACS).

METHODS

The locations of the pupil center (PC), limbal center (LC) and lens center were analyzed in each patient using optical coherence tomography during FLACS in 35 eyes of 35 patients. Using the preoperative corneal aberrometry device, angle kappa and the location of the visual axis (VA) were calculated. After acquiring the relative horizontal and vertical coordinates of each center, the distance and location among each center were compared. The relative location and distance of each center were statistically evaluated.

RESULTS

The distance from the PC to the lens center was 0.147 ± 0.103 mm, that from the LC to the lens center was 0.205 ± 0.104 mm, and that from the VA to the lens center was 0.296 ± 0.198 mm. The distance from the PC to the VA was 0.283 ± 0.161 mm, that from the LC to the VA was 0.362 ± 0.153 mm, and that from the lens center to the VA was 0.296 ± 0.198 mm. Among the various centers, the PC was the closest to the lens center, whereas the LC and VA were the farthest. Based on the location of the lens center, the PC, LC, and VA exhibited differences in the X and Y coordinate positions (vertical = 0.004, horizontal < 0.001). Among them, the LC was significantly inferior and temporal compared to the PC (vertical = 0.026, horizontal = 0.023). Based on the location of the VA, the respective locations of the PC, LC and lens center in two dimensions did not significantly differ (vertical = 0.310, horizontal = 0.926).

CONCLUSIONS

This study demonstrated the positional and locational relationships between the centers regarding FLACS. The locations of the PC, LC, and VA were different from the lens center with the PC being the closest. Surgeons should be aware of these positional relationships, especially in FLACS.

摘要

目的

分析接受飞秒激光辅助白内障手术(FLACS)患者各中心的位置关系。

方法

在35例患者的35只眼中进行FLACS手术时,使用光学相干断层扫描分析每位患者的瞳孔中心(PC)、角膜缘中心(LC)和晶状体中心的位置。使用术前角膜像差仪计算角κ和视轴(VA)的位置。获取每个中心的相对水平和垂直坐标后,比较各中心之间的距离和位置。对每个中心的相对位置和距离进行统计学评估。

结果

PC到晶状体中心的距离为0.147±0.103mm,LC到晶状体中心的距离为0.205±0.104mm,VA到晶状体中心的距离为0.296±0.198mm。PC到VA的距离为0.283±0.161mm,LC到VA的距离为0.362±0.153mm,晶状体中心到VA的距离为0.296±0.198mm。在各个中心中,PC离晶状体中心最近,而LC和VA最远。基于晶状体中心的位置,PC、LC和VA在X和Y坐标位置上存在差异(垂直方向=0.004,水平方向<0.001)。其中,与PC相比,LC明显更靠下且靠颞侧(垂直方向=0.026,水平方向=0.023)。基于VA的位置,PC、LC和晶状体中心在二维空间中的各自位置无显著差异(垂直方向=0.310,水平方向=0.926)。

结论

本研究证明了FLACS各中心之间的位置和定位关系。PC、LC和VA的位置与晶状体中心不同,PC距离最近。手术医生应了解这些位置关系,尤其是在FLACS手术中。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8df8/6372378/fe6eb6e230b5/kjo-33-70-g001.jpg

相似文献

1
Analysis of Positional Relationships of Various Centers in Cataract Surgery.
Korean J Ophthalmol. 2019 Feb;33(1):70-81. doi: 10.3341/kjo.2018.0085.
3
Femtosecond laser-assisted cataract surgery--current status and future directions.
Surv Ophthalmol. 2016 Mar-Apr;61(2):103-31. doi: 10.1016/j.survophthal.2015.09.002. Epub 2015 Sep 26.
4
5
Comparative outcomes of femtosecond laser-assisted cataract surgery and manual phacoemusification: a six-month follow-up.
Clin Exp Ophthalmol. 2016 Aug;44(6):472-80. doi: 10.1111/ceo.12695. Epub 2016 Feb 17.
7
Femtosecond laser-assisted cataract surgery in a public teaching hospital setting.
BMC Ophthalmol. 2018 Feb 2;18(1):26. doi: 10.1186/s12886-018-0693-6.
8
Femtosecond laser-assisted cataract surgery in Alport's syndrome - A case report.
Indian J Ophthalmol. 2019 Nov;67(11):1891-1893. doi: 10.4103/ijo.IJO_586_19.

引用本文的文献

本文引用的文献

2
Defining the ideal femtosecond laser capsulotomy.
Br J Ophthalmol. 2015 Aug;99(8):1137-42. doi: 10.1136/bjophthalmol-2014-306065. Epub 2015 Mar 31.
3
Angle Kappa and its importance in refractive surgery.
Oman J Ophthalmol. 2013 Sep;6(3):151-8. doi: 10.4103/0974-620X.122268.
6
Internal aberrations and optical quality after femtosecond laser anterior capsulotomy in cataract surgery.
J Refract Surg. 2011 Oct;27(10):711-6. doi: 10.3928/1081597X-20110913-01.
7
A randomized comparison of pupil-centered versus vertex-centered ablation in LASIK correction of hyperopia.
Am J Ophthalmol. 2011 Oct;152(4):591-599.e2. doi: 10.1016/j.ajo.2011.03.034. Epub 2011 Jul 2.
9
Femtosecond laser capsulotomy.
J Cataract Refract Surg. 2011 Jul;37(7):1189-98. doi: 10.1016/j.jcrs.2011.04.022.
10
Comparison of intraocular lens decentration parameters after femtosecond and manual capsulotomies.
J Refract Surg. 2011 Aug;27(8):564-9. doi: 10.3928/1081597X-20110607-01. Epub 2011 Jun 20.