The Reliability of Commonly Used Radiographic Parameters in the Evaluation of the Pre-Arthritic Hip: A Systematic Review.

作者信息

Carreira Dominic S, Emmons Brendan R

机构信息

Peachtree Orthopedics, Atlanta, Georgia.

出版信息

JBJS Rev. 2019 Feb;7(2):e3. doi: 10.2106/JBJS.RVW.18.00048.

Abstract

BACKGROUND

Radiographs play a central role in the evaluation of the extent of arthritic change and the quantification of morphological parameters characteristic of femoroacetabular impingement (FAI) and/or dysplasia. Reporting of these parameters is widespread in the literature, occasionally as an instrument for data pooling in collaborative research endeavors. Yet, the metrological properties of commonly used radiographic descriptors of acetabular and femoral architecture relevant to the field of hip preservation have not been reviewed systematically. The purpose of the present review was twofold: (1) to identify the current body of data available on the reliability of commonly used radiographic descriptors of the pre-arthritic hip and (2) to collate best practices and methodological pearls and pitfalls from the existing investigations that have explored the reliability of these radiographic measures.

METHODS

Article screening methodology involved an extensive search of 2 databases (PubMed Central, Embase). Metrological reliability data and best practices and frequencies with which these practices have been reported in existing investigations were extracted from the methods of the included studies. The radiographic parameters that were chosen as a focus for the present review were based on a discussion among a number of experienced hip-preservation surgeons.

RESULTS

Forty-three articles met all inclusion criteria and were included in this review. Eleven recurring components of study design were isolated from the included investigations as being critical for minimizing bias in the assessment of the reliability of these radiographic morphological parameters. Sixteen (37.2%) of the included studies reported the use of at least 1 quality-control measure for ensuring radiographic integrity. The radiographic parameters with the most reliability data included the lateral center-edge angle (22 studies), the Tönnis angle (14 studies), and the alpha angle (18 studies). Categorical markers of acetabular retroversion and the extent of osteoarthritis have been less-frequently studied with respect to their reliability, with the exception of the crossover sign, which was evaluated in 11 of the included studies.

CONCLUSIONS

The radiographic parameter with the most metrological evidence in support of its reliability was the lateral center-edge angle (with 22 [100%] of 22 studies reporting acceptable reliability), whereas the Tönnis grade of osteoarthritis consistently demonstrated subpar interrater and intrarater reliability. Side-arm investigations for testing reliability may be needed by individual studies to prove the validity of data-pooling practices as collaborative endeavors continue to become more widespread.

摘要

背景

X线片在评估关节炎变化程度以及量化股骨髋臼撞击症(FAI)和/或发育异常的形态学参数方面发挥着核心作用。这些参数的报告在文献中很普遍,偶尔也作为合作研究中数据汇总的工具。然而,与髋关节保留领域相关的髋臼和股骨结构常用X线描述符的计量学特性尚未得到系统综述。本综述的目的有两个:(1)确定目前关于关节炎前期髋关节常用X线描述符可靠性的现有数据;(2)整理现有研究中探索这些X线测量可靠性的最佳实践、方法要点和陷阱。

方法

文章筛选方法包括广泛检索两个数据库(PubMed Central、Embase)。从纳入研究的方法中提取计量可靠性数据、最佳实践以及这些实践在现有研究中的报告频率。作为本综述重点的X线参数是基于多位经验丰富的髋关节保留外科医生的讨论选定的。

结果

43篇文章符合所有纳入标准并被纳入本综述。从纳入研究中分离出11个反复出现的研究设计组成部分,它们对于最小化这些X线形态学参数可靠性评估中的偏差至关重要。16项(37.2%)纳入研究报告使用了至少一种质量控制措施以确保X线片的完整性。可靠性数据最多的X线参数包括外侧中心边缘角(22项研究)、Tönnis角(14项研究)和α角(18项研究)。髋臼后倾和骨关节炎程度的分类标志物在可靠性方面的研究较少,交叉征除外,纳入研究中有11项对其进行了评估。

结论

支持其可靠性的计量学证据最多的X线参数是外侧中心边缘角(22项研究中有22项[100%]报告可靠性可接受),而骨关节炎的Tönnis分级始终显示出较差的评分者间和评分者内可靠性。随着合作研究不断普及,个别研究可能需要进行补充研究以检验可靠性,从而证明数据汇总实践的有效性。