Naito Yoshihito, Yamada Shuntaro, Jinno Yohei, Arai Kazuo, Galli Silvia, Ichikawa Tetsuo, Jimbo Ryo
Int J Periodontics Restorative Dent. 2019 Mar/Apr;39(2):259-264. doi: 10.11607/prd.3220.
This study investigated the level of magnetic energy around implants possessing a static magnetic field (SMF) and assessed the in vivo influence of SMF on bone regeneration. Implants possessing a sintered neodymium magnet internally were placed in a rabbit femur. An implant without SMF was placed as control. After 12 weeks of healing in vivo, the bone samples were subjected to histologic/histomorphometric evaluation. The bone-to-implant contact for the test group and the control group were 32.4 ± 13.6% and 17.1 ± 4.5%, respectively, and the differences were statistically significant (P < .05). The results suggested that the SMF promoted new bone apposition.
本研究调查了具有静磁场(SMF)的植入物周围的磁能水平,并评估了SMF对体内骨再生的影响。将内部装有烧结钕磁铁的植入物植入兔股骨中。将无SMF的植入物作为对照。体内愈合12周后,对骨样本进行组织学/组织形态计量学评估。试验组和对照组的骨与植入物接触率分别为32.4±13.6%和17.1±4.5%,差异具有统计学意义(P<.05)。结果表明,SMF促进了新骨附着。