• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Benchmark of different assessment methods for non-sinusoidal magnetic field exposure in the context of European Directive 2013/35/EU.

作者信息

Schmid Gernot, Hirtl Rene, Samaras Theodoros

机构信息

Seibersdorf Laboratories, Dept. EMC & Optics, A-2444 Seibersdorf, Austria. Aristotle University of Thessaloniki, Dept. of Physics, GR-54124 Thessaloniki, Greece.

出版信息

J Radiol Prot. 2019 Apr;39(2):455-469. doi: 10.1088/1361-6498/ab0988. Epub 2019 Feb 22.

DOI:10.1088/1361-6498/ab0988
PMID:30794996
Abstract

For the assessment of non-sinusoidal magnetic fields the European EMF Directive 2013/35/EU specified the Weighted Peak Method in Time Domain (WPM-TD) as the reference method. However, also other scientifically validated methods are allowed, provided that they lead to approximately equivalent and comparable results. In the non-binding guide for practical implementation of 2013/35/EU three methods alternative to the WPM-TD are described, i.e. the Weighted Peak Method in Frequency Domain (WPM-FD), the Multiple Frequency Rule (MFR), and an alternative Time Domain Assessment Method (TDAM). In this paper the results of a benchmark comparison of these assessment methods, based on 12 different time domain signals of magnetic induction, measured close to real devices and nine additional generic waveforms, are presented. The results demonstrated that assessments obtained with WPM-TD and WPM-FD can be considered approximately equivalent (maximum deviation 3.4 dB). The MFR systematically overestimates exposure, due to its inherently conservative definitions. In contrast, the TDAM significantly and systematically underestimates exposure up to a factor of 22 (26.8 dB) for the considered waveforms. The main reasons for this exposure underestimation by the TDAM are the introduction of an inappropriate time averaging, and the fact that the characteristic time parameter τ , describing the minimum duration of all field changes dB/dt of the waveform is derived independently from the extent of the field change in the definitions of the TDAM. Consequently, we recommend not to use the TDAM as presently published in the non-binding guide to 2013/35/EU, as its application would be in contradiction with the underlying aim of 2013/35/EU, i.e. a harmonised level of occupational safety with respect to exposure to electromagnetic fields.

摘要

相似文献

1
Benchmark of different assessment methods for non-sinusoidal magnetic field exposure in the context of European Directive 2013/35/EU.
J Radiol Prot. 2019 Apr;39(2):455-469. doi: 10.1088/1361-6498/ab0988. Epub 2019 Feb 22.
2
Inconsistency of a recently proposed method for assessing magnetic field exposure for protection against peripheral nerve stimulation in occupational situations.
J Radiol Prot. 2016 Dec;36(4):N77-N88. doi: 10.1088/0952-4746/36/4/N77. Epub 2016 Nov 28.
3
[Experimental evaluation of the occupational exposure to static magnetic fields on a 3 T magnetic resonance scanner].[3T磁共振成像仪静磁场职业暴露的实验评估]
G Ital Med Lav Ergon. 2013 Jan-Mar;35(1):26-31.
4
Nonsinusoidalelectric field caused by magnetic deactivator device for EAS labels-assessment of field strength inside a detailed anatomical hand model.用于EAS标签的磁性去激活器装置产生的非正弦电场——在详细的手部解剖模型内的场强评估
J Radiol Prot. 2023 Feb 21;43(1). doi: 10.1088/1361-6498/acb955.
5
ASSESSMENT OF MOVEMENT-INDUCED TIME-VARYING MAGNETIC FIELDS EXPOSURE IN MAGNETIC RESONANCE IMAGING BY A COMMERCIAL PORTABLE MAGNETOMETER.使用商用便携式磁力计评估磁共振成像中运动诱发的时变磁场暴露情况。
Radiat Prot Dosimetry. 2019 Dec 31;185(3):326-330. doi: 10.1093/rpd/ncz016.
6
The Weighted Peak Method in the Time Domain Compared With Alternative Methods for Assessing LF Electric and Magnetic Fields.
Health Phys. 2017 Jul;113(1):54-65. doi: 10.1097/HP.0000000000000667.
7
[Measurement and assessment of electromagnetic fields near radiophones in line with provisions of European Directive 2013/35/EU and Polish labour law].[根据欧洲指令2013/35/EU和波兰劳动法对无线电话附近电磁场的测量与评估]
Med Pr. 2013;64(5):671-80. doi: 10.13075/mp.5893.2013.0069.
8
[Limitations of occupational exposure to electromagnetic fields adopted by Polish law from the perspectives of international documents with particular reference to fields of low and medium frequencies].[从国际文件角度看波兰法律所采用的职业性电磁场暴露限制,特别提及低频和中频电磁场领域]
Med Pr. 2003;54(3):269-78.
9
Assessment of complex EMF exposure situations including inhomogeneous field distribution.评估复杂的电磁场暴露情况,包括不均匀的场分布。
Health Phys. 2007 Jun;92(6):531-40. doi: 10.1097/01.HP.0000250620.32459.4c.
10
[National system of protection against electromagnetic fields 0 Hz-300 GHz in the light of current legal regulations].[根据现行法律法规的0赫兹至300吉赫兹电磁场国家防护体系]
Med Pr. 2006;57(2):151-9.