Graduate School of Peking Union Medical College and Chinese Academy of Medical Sciences, 9 Dongdan Santiao, Beijing, 100730, China.
National Center for Clinical Laboratories, Beijing Hospital and National Center of Gerontology, 1 Dahua Road, Beijing, 100730, China.
Anal Bioanal Chem. 2019 Apr;411(11):2363-2371. doi: 10.1007/s00216-019-01676-7. Epub 2019 Feb 26.
Measurement of serum progesterone is important in determining ovarian function. Most progesterone measurements are performed with immunoassays and results are often variable. Standardization of the measurements requires a reliable reference method. An isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS) method for the measurement of serum progesterone was developed. Serum samples were spiked with C-progesterone, extracted with a three-step liquid-liquid extraction, and analyzed by LC/MS/MS. A bracketing calibration was used for the analysis and samples were prepared gravimetrically. The developed method showed intra-run and total relative standard deviations (RSDs) of 0.500.58% and 0.711.33%, respectively. The analytical recoveries were 99.08~101.50%. Measurement results on certified reference materials obtained with this method agreed with the certified values within the stated measurement uncertainties. The method was applied to evaluate immunoassays through split-sample comparisons. A panel of 48 fresh frozen individual samples were measured with the ID-LC/MS/MS method, and six immunoassays and results were compared. Significant calibration biases and sample-specific deviations were observed on some of the immunoassays.
血清孕激素的测定对于判断卵巢功能非常重要。大多数孕激素的测定都采用免疫分析法,其结果常常存在变异性。为了实现测定的标准化,需要一种可靠的参考方法。本研究建立了一种用于血清孕激素测定的同位素稀释液相色谱串联质谱法(ID-LC/MS/MS)。采用三步液液萃取法对 C-孕激素进行了血清样本的预处理,然后通过 LC/MS/MS 进行分析。本研究采用内标法进行分析,并用重量法制备了标准曲线。该方法的批内和总相对标准偏差(RSD)分别为 0.500.58%和 0.711.33%。分析回收率为 99.08~101.50%。用该方法测定标准物质的结果与证书值在规定的测量不确定度范围内一致。通过拆分样本比较的方式,本研究将该方法应用于免疫分析的评估。采用 ID-LC/MS/MS 方法对 48 份新鲜冰冻个体样本进行了测定,并对 6 种免疫分析方法及其结果进行了比较。在某些免疫分析方法中观察到了明显的校准偏差和样本特异性偏差。