Krishna Moorthy P S, Saat S A, Sakijan A S
National Heart Institute, Department of Cardiothoracic Surgery, Kuala Lumpur, Malaysia.
National Heart Institute, Department of Radiology, Kuala Lumpur, Malaysia.
Med J Malaysia. 2019 Feb;74(1):94-96.
This is a case report of single-stage total thoracic aortic repair by the frozen elephant trunk technique for a 75-yearold female with a complex aortic pathology of mega-aorta extending from the ascending aorta to the descending aorta. We used a Thora flex™ Hybrid device, a frozen elephant trunk device with four branched grafts and the distal stent graft. The distal stent graft was inserted into the downstream descending aorta via an aortic arch and positioned 15 cm beyond the left subclavian artery after total arch replacement had been performed using a four-branch graft. The postoperative course was unremarkable with no complications. A post procedural computed tomography scan demonstrated complete exclusion of the descending thoracic aneurysm without endoleak. Therefore, fixing the whole mega-aorta in a single stage using the frozen elephant trunk was effective and safe.
这是一例采用冰冻象鼻技术进行单阶段全胸主动脉修复的病例报告,患者为一名75岁女性,患有从升主动脉延伸至降主动脉的复杂性主动脉病变——巨主动脉。我们使用了Thora flex™ Hybrid装置,这是一种带有四个分支移植物的冰冻象鼻装置和远端覆膜支架。在使用四分支移植物完成全弓置换后,将远端覆膜支架经主动脉弓插入下游降主动脉,并置于左锁骨下动脉以远15 cm处。术后病程平稳,无并发症。术后计算机断层扫描显示降胸主动脉瘤完全被隔绝,无内漏。因此,采用冰冻象鼻技术单阶段固定整个巨主动脉是有效且安全的。