Gonzalez-Lopez Felix, Bilbao-Calabuig Rafael, Mompean Blas, Luezas Jorge, Ortega-Usobiaga Julio, Druchkiv Vasyl
J Refract Surg. 2019 Mar 1;35(3):177-183. doi: 10.3928/1081597X-20190204-01.
To assess the effect of crystalline lens rise (CLR) on postoperative vault in eyes implanted with a phakic Visian Implantable Collamer Lens (ICL) (STAAR Surgical Company, Monrovia, CA) with a central port for myopic correction.
Non-invasive Fourier-domain swept-source anterior segment optical coherence tomography was used for dynamic assessment of the study eyes under changing light conditions. Phakic intraocular lens (IOL) vault, anterior chamber depth (ACD), and CLR were recorded after surgery, and intra-eye differences were analyzed under scotopic and photopic ambient light conditions. Inter-group analysis and regression analysis were performed to investigate any potential correlation between these biometric variables.
This retrospective observational study comprised 111 eyes (65 patients) implanted with a myopic Visian ICL. The mean change in CLR from mydriasis to miosis was 59 ± 60 µm (P < .001). The sample was further divided into four groups according to the CLR value in miosis: CLR < 0, 0 to 200, 201 to 350, and > 350 µm. A significant difference in central vault values was observed between the < 0 and > 350 µm groups, the 0 to 200 and 201 to 350 µm groups, and the 0 to 200 and > 350 µm groups (P < .05). Eyes with a high vault value (> 750 µm in mydriasis) had lower CLR values (P < .001) and higher ACD values (P < .001) than eyes with a low vault value (< 100 µm in miosis). The linear correlation observed was negative between CLR and ACD, positive between postoperative vault and ACD, and negative between postoperative vault and CLR (P < .001).
CLR significantly affected anterior chamber depth and postoperative ICL vault. [J Refract Surg. 2019;35(3):177-183.].
评估晶状体上升(CLR)对植入有用于近视矫正的中央端口的有晶状体眼Visian可植入式胶原晶状体(ICL)(STAAR Surgical Company,蒙罗维亚,加利福尼亚州)的眼睛术后房高的影响。
使用非侵入性傅里叶域扫频源眼前节光学相干断层扫描在变化的光照条件下对研究眼进行动态评估。术后记录有晶状体眼人工晶状体(IOL)房高、前房深度(ACD)和CLR,并在暗视和明视环境光条件下分析眼内差异。进行组间分析和回归分析以研究这些生物测量变量之间的任何潜在相关性。
这项回顾性观察研究包括111只植入近视Visian ICL的眼睛(65例患者)。从散瞳到缩瞳CLR的平均变化为59±60μm(P <.001)。根据缩瞳时的CLR值将样本进一步分为四组:CLR <0、0至200、201至350和> 350μm。在<0和> 350μm组、0至200和201至350μm组以及0至200和> 350μm组之间观察到中央房高值存在显著差异(P <.05)。房高值高的眼睛(散瞳时> 750μm)与房高值低的眼睛(缩瞳时<100μm)相比,CLR值较低(P <.001),ACD值较高(P <.001)。观察到的线性相关性为CLR与ACD之间呈负相关,术后房高与ACD之间呈正相关,术后房高与CLR之间呈负相关(P <.001)。
CLR显著影响前房深度和术后ICL房高。[《屈光手术杂志》。2019;35(3):177 - 183。]