We compared measurements of apoprotein A-I (apoA-I) in plasma and in heparin-MnCl2 supernates analyzed by radial immunodiffusion. The apoA-I values were similar when the samples were fresh [n = 41, mean (SD), mg/L: plasma, 1393.4(349); heparin-MnCl2 supernates, 1364.9(332), p less than 0.01], but were greater than 8% lower in heparin-MnCl2 supernates after storage for seven days at 4 degrees C [plasma, 1348.0(351); heparin-MnCl2 supernates, 1237.6(342), p less than 0.001]. Neither heparin nor MnCl2 interfered directly with the immunodiffusion assay, and treating samples with tetramethylurea and urea to maximize the exposure of apoA-I did not prevent the decrease. MnCl2 (46 mmol/L) added to isolated HDL (d 1.063-1.21) decreased apoA-I values by 5.6% when measured immediately and by 16.7% after storage at 4 degrees C for seven days. High-density lipoprotein cholesterol values were unchanged by MnCl2. The results indicated that apoA-I was more stable in plasma than in heparin-MnCl2 supernates, probably because of an interaction between apoA-I and MnCl2.

摘要

我们比较了通过放射免疫扩散法分析的血浆和肝素 - 氯化锰上清液中载脂蛋白A - I(apoA - I)的测量值。当样本新鲜时,apoA - I值相似[n = 41,平均值(标准差),mg/L:血浆,1393.4(349);肝素 - 氯化锰上清液,1364.9(332),p < 0.01],但在4℃储存7天后,肝素 - 氯化锰上清液中的值比血浆中的值低超过8%[血浆,1348.0(351);肝素 - 氯化锰上清液,1237.6(342),p < 0.001]。肝素和氯化锰均未直接干扰免疫扩散测定,并且用四甲基脲和尿素处理样本以最大程度地暴露apoA - I并不能阻止其下降。向分离的高密度脂蛋白(d 1.063 - 1.21)中添加46 mmol/L的氯化锰,立即测量时apoA - I值降低5.6%,在4℃储存7天后降低16.7%。高密度脂蛋白胆固醇值不受氯化锰影响。结果表明,apoA - I在血浆中比在肝素 - 氯化锰上清液中更稳定,这可能是由于apoA - I与氯化锰之间的相互作用。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验