The National Institute for Health Research (NIHR) Oxford Biomedical Research Centre, Oxford University Hospitals NHS Foundation Trust, Oxford, United Kingdom.
Royal Devon and Exeter NHS Foundation Trust, Exeter, United Kingdom.
Transfusion. 2019 May;59(5):1683-1691. doi: 10.1111/trf.15231. Epub 2019 Mar 12.
This multicenter international study evaluated electronic remote blood issue (ERBI) for blood unit collection in hospitals.
Retrospective data were collected from the ERBI software databases and blood bank information systems. Prospective "time-and-motion" data collection methods simulated the delivery of red blood cell units to determine the staff time for each step.
The main benefit of ERBI was found in two hospitals where the blood unit was issued and collected at refrigerators remote from the blood bank (closer to the clinical area) compared with the standard process of blood bank issue (BBI) and blood unit collection in the blood bank. There was a reduction in the time for blood to reach patients (2.02 min compared to 8.43 min at one site [p ≤ 0.0001], 1.57 min compared to 6.54 min at the other [p ≤ 0.0001]). However, there was no reduction in time where ERBI was conducted in the blood bank or where a blood unit issued by the standard BBI was collected at remote refrigerators. In the three hospitals where ERBI was conducted at remote refrigerators, there was an improved issue:transfusion ratio (range of 1.02-1.09 for ERBI compared to 1.48-1.58 for BBI) and a reduction in staff time and costs of between $5,000 and $10,000/year.
This multicenter international study builds on findings from studies in single hospitals that ERBI at remote refrigerators improves the efficiency of transfusion by reducing the time taken for blood units to reach patients, staff time, and costs.
这项多中心国际研究评估了电子远程采血(ERBI)在医院中用于血液采集的效果。
回顾性数据来自 ERBI 软件数据库和血库信息系统。前瞻性“时间与动作”数据收集方法模拟了红细胞单位的输送,以确定每个步骤的员工时间。
在两家医院中,ERBI 的主要优势在于,与标准的血库发放(BBI)和血库中血液采集流程相比,血液单位在远离血库(更接近临床区域)的冰箱中发放和采集。血液到达患者的时间有所缩短(一个地点的 2.02 分钟与 8.43 分钟相比[P≤0.0001],另一个地点的 1.57 分钟与 6.54 分钟相比[P≤0.0001])。然而,在血库中进行 ERBI 或在远程冰箱中采集由标准 BBI 发放的血液单元时,时间并没有缩短。在三个在远程冰箱中进行 ERBI 的医院中,发血:输血比例(ERBI 为 1.02-1.09,BBI 为 1.48-1.58)得到改善,员工时间和成本减少了 5000 至 10000 美元/年。
这项多中心国际研究建立在单个医院研究结果的基础上,表明在远程冰箱中进行 ERBI 可以通过缩短血液到达患者的时间、员工时间和成本,提高输血效率。