Abstract

BACKGROUND/PURPOSE: Heat treatment of nickel-titanium (NiTi) alloy produces a better arrangement of the crystal structure, thereby leading to increased flexibility and improved fatigue resistance or plastic behavior. This study aimed to assess the performance of various heat-treated NiTi rotary instruments in S-shaped resin canals.

MATERIALS AND METHODS

Forty S-shaped resin canals were instrumented (10/group) with either Twisted Files (R-phase), WaveOne (M-wire), Hyflex CM, or V Taper 2H (CM-wire) with the same apical size and taper (25/0.08). Each S-shaped resin canal was scanned both before and after instrumentation with microcomputed tomography. Changes in canal volume and transportation were evaluated at regular intervals (0.5 mm). Differences between instruments at the apical curve, coronal curve, and straight portion of the canals were analyzed statistically.

RESULTS

All tested instruments caused more transportation at the coronal rather than apical curvatures, with the exception of Twisted Files for which apical transportation was the highest for any instrument or location (P < 0.05). The transportation was mostly influenced by the alloy type rather than their cross-sectional characteristics (P < 0.05). The volumetric increase after instrumentation was similar for all tested instruments at the apical curve (P > 0.05), whereas Hyflex CM created the most conservative preparations at the coronal curve (P < 0.05). At the straight portion, volumetric changes were largest for Twisted Files and smallest for V Taper 2H (P < 0.05).

CONCLUSION

Amongst heat-treated NiTi instruments, the CM-wire based instruments created the most favorable preparations in S-shaped resin canals.

摘要

背景/目的:镍钛(NiTi)合金的热处理可使晶体结构排列更优,从而提高柔韧性、增强抗疲劳性或改善塑性行为。本研究旨在评估各种热处理后的NiTi旋转器械在S形树脂根管中的性能。

材料与方法

40个S形树脂根管(每组10个)分别用相同根尖尺寸和锥度(25/0.08)的Twisted Files(R相)、WaveOne(M丝)、Hyflex CM或V Taper 2H(CM丝)器械进行预备。每个S形树脂根管在预备前后均用微型计算机断层扫描进行扫描。定期(0.5毫米)评估根管容积和偏移情况。对器械在根管根尖弯曲处、冠部弯曲处和直管段的差异进行统计学分析。

结果

所有测试器械在冠部弯曲处造成的偏移均多于根尖弯曲处,但Twisted Files除外,其在任何器械或位置的根尖偏移量均为最高(P < 0.05)。偏移主要受合金类型而非横截面特征的影响(P < 0.05)。所有测试器械在根尖弯曲处预备后的容积增加相似(P > 0.05),而Hyflex CM在冠部弯曲处的预备最为保守(P < 0.05)。在直管段,Twisted Files的容积变化最大,V Taper 2H的最小(P < 0.05)。

结论

在热处理后的NiTi器械中,基于CM丝的器械在S形树脂根管中能产生最理想的预备效果。