Central Laboratory of Analyses, IRCCS Istituto Giannina Gaslini, Genoa, Italy.
Infectious Diseases Unit, IRCCS Istituto Giannina Gaslini, Genoa, Italy.
J Pharm Biomed Anal. 2019 Jun 5;170:193-195. doi: 10.1016/j.jpba.2019.03.023. Epub 2019 Mar 14.
Starting from a warning of possible artificially high plasma colistin concentrations observed in clinical samples in our recently published LC-MS/MS method, we reviewed our analytical assay and demonstrated, for the first time, that caution must be paid to ionization conditions employed in the MS system. The artefact reported here demonstrates that additional experiments should be performed in the course of validation of LC-MS/MS methods to be used in samples containing both colistin and colistimethate.
从我们最近发表的 LC-MS/MS 方法中观察到临床样本中可能存在人为高血浆多粘菌素浓度的警告出发,我们回顾了我们的分析方法,并首次证明必须注意 MS 系统中采用的离子化条件。这里报道的人为产物表明,在含有多粘菌素和粘菌素甲磺酸盐的样品中使用 LC-MS/MS 方法的验证过程中,应该进行额外的实验。