Suppr超能文献

比较布罗迪公式与呼吸气体分析用于估计麻醉犬的耗氧量。

Comparison of Brody's formula with respiratory gas analysis for estimating oxygen consumption in anaesthetized dogs.

作者信息

Borland Karla J, Bennett Rachel, Clutton R Eddie

机构信息

Royal (Dick) School of Veterinary Studies, University of Edinburgh, Easter Bush, Roslin, Edinburgh, Scotland, UK; Anderson Moores Veterinary Specialists, Winchester, UK.

Anderson Moores Veterinary Specialists, Winchester, UK.

出版信息

Vet Anaesth Analg. 2019 May;46(3):365-368. doi: 10.1016/j.vaa.2018.11.008. Epub 2019 Feb 23.

Abstract

OBJECTIVE

To determine agreement in oxygen consumption (V˙O) values calculated using Sykes' formula V˙O = (FiO - Fe'O) * V˙ (where Fi and Fe are the inspired and end-tidal fractional concentrations of O, respectively, and V˙ is minute volume) with values derived using Brody's formula (V˙O = 10 kg). It was hypothesized that the two methods would not yield statistically significant differences in calculated values.

STUDY DESIGN

Prospective, clinical, pilot study.

ANIMALS

A total of 22 client-owned dogs.

METHODS

Dogs undergoing surgery were anaesthetized with either isoflurane or sevoflurane. The V˙, FiO and Fe'O were measured during mechanical ventilation of the lungs (tidal volume 10 mL kg; respiratory rate: 8-12 breaths minute). Oesophageal temperature was maintained between 37.0 °C and 38.5 °C. Values for V˙O derived by Sykes' and Brody's methods were compared and agreement was determined using Bland-Altman analysis.

RESULTS

Mean V˙O values were 4.67 ± 0.51 mL kg minute and 5.32 ± 1.69 mL kg minute calculated using Brody's formula and Sykes' equation, respectively. There was greater variability in the values obtained from Sykes' equation. The Bland-Altman plot revealed a proportional error with correlation but poor agreement between values.

CONCLUSIONS AND CLINICAL RELEVANCE

Both methods yielded V˙O values of approximately 5 mL kgminute with no statistically significant differences between the two methods.

摘要

目的

确定使用赛克斯公式(V˙O = (FiO - Fe'O) * V˙,其中Fi和Fe分别为吸入气和呼出气中氧的分数浓度,V˙为分钟通气量)计算的耗氧量(V˙O)值与使用布罗迪公式(V˙O = 10 kg)得出的值之间的一致性。假设两种方法计算出的值在统计学上无显著差异。

研究设计

前瞻性、临床、试点研究。

动物

总共22只客户拥有的犬。

方法

接受手术的犬用异氟烷或七氟烷麻醉。在肺机械通气期间(潮气量10 mL/kg;呼吸频率:8 - 12次/分钟)测量V˙、FiO和Fe'O。食管温度维持在37.0℃至38.5℃之间。比较赛克斯法和布罗迪法得出的V˙O值,并使用布兰德 - 奥特曼分析确定一致性。

结果

使用布罗迪公式和赛克斯公式计算的平均V˙O值分别为4.67±0.51 mL/kg·分钟和5.32±1.69 mL/kg·分钟。从赛克斯公式获得的值变异性更大。布兰德 - 奥特曼图显示存在相关性的比例误差,但值之间的一致性较差。

结论及临床意义

两种方法得出的V˙O值均约为5 mL/kg·分钟,两种方法之间无统计学显著差异。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验