Mehmood Zahid, Haneef Ibraheem, Ali Syed Zeeshan, Udrea Florin
Engineering Department, University of Cambridge, Cambridge CB3 0FA, UK.
Institute of Avionics & Aeronautics, Air University, E-9, Islamabad 44000, Pakistan.
Sensors (Basel). 2019 Apr 18;19(8):1860. doi: 10.3390/s19081860.
Minimizing conductive heat losses in Micro-Electro-Mechanical-Systems (MEMS) thermal (hot-film) flow sensors is the key to minimize the sensors' power consumption and maximize their sensitivity. Through a comprehensive review of literature on MEMS thermal (calorimetric, time of flight, hot-film/hot-film) flow sensors published during the last two decades, we establish that for curtailing conductive heat losses in the sensors, researchers have either used low thermal conductivity substrate materials or, as a more effective solution, created low thermal conductivity membranes under the heaters/hot-films. However, no systematic experimental study exists that investigates the effect of membrane shape, membrane size, heater/hot-film length and M e m b r a n e (size) to H e a t e r (hot-film length) () on sensors' conductive heat losses. Therefore, in this paper we have provided experimental evidence of dependence of conductive heat losses in membrane based MEMS hot-film flow sensors on by using eight MEMS hot-film flow sensors, fabricated in a 1 µm silicon-on-insulator (SOI) CMOS foundry, that are thermally isolated by square and circular membranes. Experimental results demonstrate that: (a) thermal resistance of both square and circular membrane hot-film sensors increases with increasing , and (b) conduction losses in square membrane based hot-film flow sensors are lower than the sensors having circular membrane. The difference (or gain) in thermal resistance of square membrane hot-film flow sensors viz-a-viz the sensors on circular membrane, however, decreases with increasing . At = 2, this difference is 5.2%, which reduces to 3.0% and 2.6% at = 3 and = 4, respectively. The study establishes that for membrane based SOI CMOS MEMS hot-film sensors, the optimum is 3.35 for square membranes and 3.30 for circular membranes, beyond which the gain in sensors' thermal efficiency (thermal resistance) is not economical due to the associated sharp increase in the sensors' (membrane) size, which makes sensors more expensive as well as fragile. This paper hence, provides a key guideline to MEMS researchers for designing the square and circular membranes-supported micro-machined thermal (hot-film) flow sensors that are thermally most-efficient, mechanically robust and economically viable.
在微机电系统(MEMS)热式(热膜)流量传感器中,尽量减少传导热损失是降低传感器功耗并最大化其灵敏度的关键。通过全面回顾过去二十年发表的关于MEMS热式(量热式、飞行时间式、热膜/热膜)流量传感器的文献,我们发现,为了减少传感器中的传导热损失,研究人员要么使用低导热率的衬底材料,要么作为一种更有效的解决方案,在加热器/热膜下方制造低导热率的薄膜。然而,目前尚无系统的实验研究来探究薄膜形状、薄膜尺寸、加热器/热膜长度以及薄膜(尺寸)与加热器(热膜长度)的比值()对传感器传导热损失的影响。因此,在本文中,我们通过使用八个在1μm绝缘体上硅(SOI)CMOS工艺中制造的MEMS热膜流量传感器,提供了基于薄膜的MEMS热膜流量传感器中传导热损失与比值的依赖关系的实验证据,这些传感器通过方形和圆形薄膜实现热隔离。实验结果表明:(a)方形和圆形薄膜热膜传感器的热阻均随比值的增加而增加,(b)基于方形薄膜的热膜流量传感器中的传导损失低于具有圆形薄膜的传感器。然而,方形薄膜热膜流量传感器与圆形薄膜传感器相比,热阻的差异(或增益)随比值的增加而减小。在 = 2时,这种差异为5.2%,在 = 3和 = 4时分别降至3.0%和2.6%。该研究表明,对于基于薄膜的SOI CMOS MEMS热膜传感器,方形薄膜的最佳比值为3.35,圆形薄膜为3.30,超过该值,由于传感器(薄膜)尺寸的急剧增加,传感器热效率(热阻)的增益在经济上并不划算,这使得传感器更昂贵且更易碎。因此,本文为MEMS研究人员设计方形和圆形薄膜支撑的微机械热式(热膜)流量传感器提供了关键指导,这些传感器在热效率、机械强度和经济可行性方面都是最佳的。