OBJECTIVE

To compare the diagnostic performance of the manual BACTEC™ Mycobacteria Growth Indicator Tube (MGIT™) system (M-MGIT) with the automated BACTEC™ MGIT™ 960 system (A-MGIT) and Löwenstein-Jensen (L-J) culture method in detecting mycobacteria in sputum specimens from patients with suspected pulmonary tuberculosis (TB).

METHODS

For this cross-sectional study, sputum samples were taken from patients aged ≥18 years attending a TB clinic in Beijing, China between July 2015 and October 2016. Processed sputum samples were inoculated into the MGIT systems and L-J medium for up to 6 and 8 weeks, respectively.

RESULTS

The M-MGIT and A-MGIT methods detected significantly more Mycobacterium tuberculosis complex (MTC) isolates than L-J culture from the 565 sputum samples (39%, 40% and 32%, respectively). Using a positive result from any of the three culture systems as reference, the sensitivity of M-MGIT, A-MGIT and L-J methods were 92%, 94%, and 74%, respectively. The time-to-detection of mycobacteria was 12.9±4.2 days for M-MGIT, 11.8±5.2 days for A-MGIT and 24.2±8.7 days for L-J.

CONCLUSIONS

M-MGIT has a similar diagnostic performance to A-MGIT, and is a fast and reliable alternative to conventional culture methods in the diagnosis of pulmonary TB in a developing country.

摘要

目的

比较手动BACTEC™分枝杆菌生长指示管(MGIT™)系统(M-MGIT)、自动BACTEC™ MGIT™ 960系统(A-MGIT)和罗-琴(L-J)培养法在检测疑似肺结核(TB)患者痰液标本中分枝杆菌的诊断性能。

方法

在这项横断面研究中,于2015年7月至2016年10月期间,从中国北京一家结核病诊所就诊的年龄≥18岁的患者中采集痰液样本。处理后的痰液样本分别接种到MGIT系统和L-J培养基中,培养时间分别长达6周和8周。

结果

在565份痰液样本中,M-MGIT和A-MGIT方法检测到的结核分枝杆菌复合群(MTC)分离株显著多于L-J培养法(分别为39%、40%和32%)。以三种培养系统中任何一种的阳性结果为参照,M-MGIT、A-MGIT和L-J方法的灵敏度分别为92%、94%和74%。M-MGIT检测分枝杆菌的时间为12.9±4.2天,A-MGIT为11.8±5.2天,L-J为24.2±8.7天。

结论

M-MGIT与A-MGIT具有相似的诊断性能,在发展中国家诊断肺结核时,是一种快速且可靠的传统培养方法替代方案。

相似文献

本文引用的文献

4
Diagnosis of pulmonary tuberculosis: recent advances and diagnostic algorithms.肺结核的诊断:最新进展与诊断算法
Tuberc Respir Dis (Seoul). 2015 Apr;78(2):64-71. doi: 10.4046/trd.2015.78.2.64. Epub 2015 Apr 2.
8
Rapid molecular detection of tuberculosis and rifampin resistance.快速分子检测结核分枝杆菌及利福平耐药性。
N Engl J Med. 2010 Sep 9;363(11):1005-15. doi: 10.1056/NEJMoa0907847. Epub 2010 Sep 1.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验