Hanna B A, Ebrahimzadeh A, Elliott L B, Morgan M A, Novak S M, Rusch-Gerdes S, Acio M, Dunbar D F, Holmes T M, Rexer C H, Savthyakumar C, Vannier A M
New York University School of Medicine, Bellevue Hospital, New York, New York, USA.
J Clin Microbiol. 1999 Mar;37(3):748-52. doi: 10.1128/JCM.37.3.748-752.1999.
We evaluated the BACTEC MGIT 960 system, which is a fully automated, noninvasive system for the growth and detection of mycobacteria with a capacity to incubate and continuously monitor 960 7-ml culture tubes. We studied 3,330 specimens, 2,210 respiratory and 1,120 nonrespiratory specimens, collected from 2,346 patients treated at six sites. Processed specimens were inoculated into the BACTEC MGIT 960 and BACTEC 460 TB systems, as well as onto Lowenstein-Jensen slants and Middlebrook 7H11/7H11 selective plates. From all culture systems, a total of 362 isolates of mycobacteria were recovered; these were recovered from 353 specimens collected from 247 patients. The greatest number of isolates of mycobacteria (289, or 80% of the 362 isolates) was recovered with the BACTEC MGIT 960, followed by the BACTEC 460 TB (271, or 75%) and solid media (250, or 69%). From all culture systems a total of 132 isolates of Mycobacterium tuberculosis complex were recovered. The greatest number of isolates of M. tuberculosis complex was recovered when liquid medium was combined with conventional solid media; the number recovered with BACTEC 460 TB plus solid media was 128 (97%), that recovered with BACTEC MGIT 960 plus solid media was 121 (92%), that recovered with BACTEC 460 TB was 119 (90%) and that recovered with all solid media combined was 105 (79%). The recovery with BACTEC MGIT 960 alone was 102 (77%). The mean times to detection (TTD) for M. tuberculosis complex were 14.4 days for BACTEC MGIT, 15.2 days for BACTEC 460 TB, and 24.1 days for solid media. The numbers of isolates of Mycobacterium avium complex (MAC) recovered were 172 (100%) for all systems, 147 (85%) for BACTEC MGIT 960, 123 (72%) for BACTEC 460 TB, and 106 (62%) for all solid media combined. The TTD for MAC in each system were 10.0 days for BACTEC MGIT 960, 10.4 days for BACTEC 460 TB, and 25.9 days for solid media. Breakthrough contamination rates (percentages of isolates) for each of the systems were 8.1% for BACTEC MGIT 960, 4.9% for BACTEC 460 TB, and 21.1% for all solid media combined.
我们评估了BACTEC MGIT 960系统,这是一种用于分枝杆菌培养和检测的全自动、非侵入性系统,能够对960支7毫升培养管进行孵育并持续监测。我们研究了从6个地点接受治疗的2346例患者采集的3330份标本,其中2210份为呼吸道标本,1120份为非呼吸道标本。将处理后的标本接种到BACTEC MGIT 960和BACTEC 460 TB系统以及罗-琴斜面和Middlebrook 7H11/7H11选择性平板上。从所有培养系统中,共分离出362株分枝杆菌;这些菌株来自247例患者的353份标本。分枝杆菌分离株数量最多的是BACTEC MGIT 960系统(289株,占362株分离株的80%),其次是BACTEC 460 TB系统(271株,占75%)和固体培养基(250株,占69%)。从所有培养系统中,共分离出132株结核分枝杆菌复合群菌株。当液体培养基与传统固体培养基联合使用时,结核分枝杆菌复合群分离株数量最多;BACTEC 460 TB加固体培养基分离出128株(97%),BACTEC MGIT 960加固体培养基分离出121株(92%),BACTEC 460 TB分离出119株(90%),所有固体培养基联合使用分离出105株(79%)。单独使用BACTEC MGIT 960分离出102株(77%)。结核分枝杆菌复合群的平均检测时间(TTD)为:BACTEC MGIT系统为14.4天,BACTEC 460 TB系统为15.2天,固体培养基为24.1天。鸟分枝杆菌复合群(MAC)的分离株数量在所有系统中为172株(100%),BACTEC MGIT 960系统为147株(85%),BACTEC 460 TB系统为123株(72%),所有固体培养基联合使用为106株(62%)。各系统中MAC的TTD为:BACTEC MGIT 960系统为10.0天,BACTEC 460 TB系统为10.4天,固体培养基为25.9天。各系统的污染突破率(分离株百分比)为:BACTEC MGIT 960系统为8.1%,BACTEC 460 TB系统为4.9%,所有固体培养基联合使用为21.1%。