应用径向 GRAPPA 技术于单/多层动态言语 MRI 检查:使用 16 通道神经血管线圈。

Application of radial GRAPPA techniques to single- and multislice dynamic speech MRI using a 16-channel neurovascular coil.

机构信息

Clinical Physics, Barts Health NHS Trust, St Bartholomew's Hospital, London, United Kingdom.

William Harvey Research Institute, Queen Mary University of London, Charterhouse Square, London, United Kingdom.

出版信息

Magn Reson Med. 2019 Sep;82(3):948-958. doi: 10.1002/mrm.27779. Epub 2019 Apr 24.

Abstract

PURPOSE

To investigate: (1) the feasibility of using through-time radial GeneRalized Autocalibrating Partially Parallel Acquisitions (rGRAPPA) and hybrid radial GRAPPA (h-rGRAPPA) in single- and multislice dynamic speech MRI; (2) whether single-slice dynamic speech MRI at a rate of 15 frames per second (fps) or higher and with adequate image quality can be achieved using these radial GRAPPA techniques.

METHODS

Seven healthy adult volunteers were imaged at 3T using a 16-channel neurovascular coil and 2 spoiled gradient echo sequences (radial trajectory, field of view = 192 × 192 mm , acquired pixel size = 2.4 × 2.4 mm ). One sequence imaged a single slice at 16.8 fps, the other imaged 2 interleaved slices at 7.8 fps per slice. Image sets were reconstructed using rGRAPPA and h-rGRAPPA, and their image quality was compared using the root mean square error, structural similarity index, and visual assessments.

RESULTS

Image quality deteriorated when fewer than 170 calibration frames were used in the rGRAPPA reconstruction. rGRAPPA image sets demonstrated: (1) in 97% of cases, a similar image quality to h-rGRAPPA image sets reconstructed using a k-space segment size of 4, (2) in 98% of cases, a better image quality than h-rGRAPPA image sets reconstructed using a k-space segment size of 32.

CONCLUSION

This study confirmed: (1) the feasibility of using rGRAPPA and h-rGRAPPA in single- and multislice dynamic speech MRI, (2) that single-slice speech imaging at a frame rate higher than 15 fps and with adequate image quality can be achieved using these radial GRAPPA techniques.

摘要

目的

研究:(1)在单和多层面动态语音 MRI 中使用时变径向广义自校准部分并行采集(rGRAPPA)和混合径向 GRAPPA(h-rGRAPPA)的可行性;(2)这些径向 GRAPPA 技术是否可以实现 15 帧/秒(fps)或更高的单层面动态语音 MRI 以及足够的图像质量。

方法

在 3T 下,使用 16 通道神经血管线圈和 2 个扰相梯度回波序列(径向轨迹,视野=192×192mm,采集像素大小=2.4×2.4mm)对 7 名健康成年志愿者进行成像。一个序列以 16.8fps 成像单个层面,另一个序列以 7.8fps/层的速度成像 2 个层间层面。使用 rGRAPPA 和 h-rGRAPPA 重建图像集,并使用均方根误差、结构相似性指数和视觉评估来比较它们的图像质量。

结果

当 rGRAPPA 重建中使用的校准帧数少于 170 时,图像质量会恶化。rGRAPPA 图像集表现出:(1)在 97%的情况下,与使用 k 空间段大小为 4 的 h-rGRAPPA 图像集重建的图像质量相似,(2)在 98%的情况下,与使用 k 空间段大小为 32 的 h-rGRAPPA 图像集重建的图像质量更好。

结论

本研究证实:(1)在单和多层面动态语音 MRI 中使用 rGRAPPA 和 h-rGRAPPA 的可行性,(2)这些径向 GRAPPA 技术可以实现高于 15fps 的单层面语音成像和足够的图像质量。

文献检索