To characterize hemostatic profiles in dogs with acute pancreatitis.
Prospective and observational study.
Tertiary referral centers.
Fifteen client-owned dogs with acute pancreatitis enrolled between December 1, 2011 and June 1, 2012.
Blood samples were collected on admission for measurement of platelet count, PCV, thromboelastography (TEG), antithrombin, prothrombin time, activated partial thromboplastin time, D-dimer, von Willebrand factor, and fibrinogen values, which were compared to reference intervals derived from healthy dogs. The Wilcoxon rank-sum test was used to test for differences in continuous variables between study subjects and reference intervals.
Dogs with acute pancreatitis were globally hypercoagulable using TEG when compared with reference intervals. Dogs with acute pancreatitis had significantly higher D-dimers (1,144 μg/L vs 251 μg/L [6264.5 vs 1374.5 nmol/L]; P = 0.001), fibrinogen (837 vs 232 mg/dL [8.37 vs 2.32 g/L]; P < 0.001), and von Willebrand factor (92.9% vs 65.1%; P = 0.02) as well as significantly lower antithrombin (85.7% vs 120%; P < 0.001) and prothrombin time values (3.8 vs 7.6 sec; P < 0.001) than reference intervals.
Laboratory evidence of hypercoagulability was present in dogs with acute pancreatitis. TEG may be useful in dogs with acute pancreatitis for monitoring response to therapy and guiding therapeutic interventions.
描述急性胰腺炎犬的止血情况。
前瞻性观察研究。
三级转诊中心。
2011年12月1日至2012年6月1日期间纳入的15只客户拥有的急性胰腺炎犬。
入院时采集血样,测定血小板计数、红细胞压积、血栓弹力图(TEG)、抗凝血酶、凝血酶原时间、活化部分凝血活酶时间、D - 二聚体、血管性血友病因子和纤维蛋白原值,并与健康犬的参考区间进行比较。采用Wilcoxon秩和检验来检验研究对象与参考区间之间连续变量的差异。
与参考区间相比,急性胰腺炎犬使用TEG时整体处于高凝状态。急性胰腺炎犬的D - 二聚体(1144μg/L对251μg/L [6264.5对1374.5nmol/L];P = 0.001)、纤维蛋白原(837对232mg/dL [8.37对2.32g/L];P < 0.001)和血管性血友病因子(92.9%对65.1%;P = 0.02)显著更高,而抗凝血酶(85.7%对120%;P < 0.001)和凝血酶原时间值(3.8对7.6秒;P < 0.001)显著低于参考区间。
急性胰腺炎犬存在高凝状态的实验室证据。TEG可能有助于急性胰腺炎犬监测治疗反应和指导治疗干预。