Suppr超能文献

健康犬凝血功能的 TEG 6s 和 TEG 5000 可视化分析仪评估比较。

Comparison of assessment of coagulation in healthy dogs by the TEG 6s and TEG 5000 viscoelastic analyzers.

机构信息

College of Veterinary Medicine, Texas A&M University, College Station, TX, USA.

U.S. Army Institute of Surgical Research, JBSA Fort Sam Houston, TX, USA.

出版信息

J Vet Diagn Invest. 2022 Sep;34(5):780-788. doi: 10.1177/10406387221112638. Epub 2022 Jul 19.

Abstract

The TEG 6s (Haemonetics) point-of-care viscoelastic analyzer is portable, compact, simple to use, and has the potential for rapid viscoelastic analysis that can guide the treatment of veterinary patients at the site of care. Although approved for use in people, the TEG 6s has yet to be evaluated for hemostatic analysis in veterinary medicine. Citrated whole blood (CWB) was collected from 27 healthy dogs. An aliquot of CWB from each dog was diluted by 33% with an isotonic crystalloid, representing an in vitro model of hemodilution. Unaltered and diluted CWB samples were analyzed using 2 TEG 6s and 6 TEG 5000 (Haemonetics) analyzers. The 6 TEG 5000 analyzers ran duplicate analyses of either unaltered or diluted samples using 1 of 3 reagents (Haemonetics): Kaolin TEG, RapidTEG, or TEG Functional Fibrinogen. Duplicate TEG 5000 analyses were averaged and compared with a single TEG 6s analysis. Lin concordance correlation coefficient and Bland-Altman plots were used to evaluate agreement of reaction time, kinetic time, alpha angle, maximum amplitude (MA), and G value (G) for samples activated with Kaolin TEG, and agreement of MA for samples activated with RapidTEG between the 2 machines. Overall, agreement between the TEG 6s and TEG 5000 analyzers was poor. Viscoelastic measurements by the TEG 6s and TEG 5000 in healthy dogs were not all interchangeable. Agreement was satisfactory only for MA and G measurements of diluted blood samples activated with Kaolin TEG, and MA measurements for both unaltered and diluted blood samples activated with RapidTEG.

摘要

TEG 6s(Haemonetics)即时凝血分析仪便于携带,结构紧凑,操作简单,并且具有快速检测的潜力,能够指导现场护理的兽医患者的治疗。尽管该仪器已获准用于人体,但尚未对其在兽医领域的止血分析进行评估。从 27 只健康犬中采集枸橼酸盐全血(CWB)。将每只犬的 CWB 等分试样用等渗晶体稀释 33%,代表体外血液稀释模型。使用 2 台 TEG 6s 和 6 台 TEG 5000(Haemonetics)分析仪对未稀释和稀释的 CWB 样本进行分析。6 台 TEG 5000 分析仪使用 3 种试剂(Haemonetics)之一对未稀释或稀释的样本进行重复分析:高岭土 TEG、RapidTEG 或 TEG 功能纤维蛋白原。重复的 TEG 5000 分析结果取平均值,并与单一 TEG 6s 分析结果进行比较。采用林氏一致性相关系数和 Bland-Altman 图评估 2 种仪器之间用高岭土 TEG 激活的样本的反应时间、动力学时间、α 角、最大振幅(MA)和 G 值(G)以及用 RapidTEG 激活的样本的 MA 的一致性。总的来说,TEG 6s 和 TEG 5000 分析仪之间的一致性较差。健康犬的 TEG 6s 和 TEG 5000 检测的粘弹性测量值并非完全可互换。仅在使用高岭土 TEG 激活的稀释血液样本的 MA 和 G 测量值以及使用 RapidTEG 激活的未稀释和稀释血液样本的 MA 测量值方面具有满意的一致性。

相似文献

本文引用的文献

4
Use of Thromboelastography in Clinical Practice.血栓弹力描记术的临床应用。
Vet Clin North Am Small Anim Pract. 2020 Nov;50(6):1397-1409. doi: 10.1016/j.cvsm.2020.08.001.
7
The current status of viscoelastic testing in septic coagulopathy.脓毒症凝血障碍中黏弹性检测的现状。
Thromb Res. 2019 Nov;183:146-152. doi: 10.1016/j.thromres.2019.09.029. Epub 2019 Oct 23.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验