Suppr超能文献

静态与动态计算机辅助种植手术在单个牙缺失位点的准确性:一项随机对照试验。

The accuracy of static vs. dynamic computer-assisted implant surgery in single tooth space: A randomized controlled trial.

机构信息

Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand.

Department of Radiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand.

出版信息

Clin Oral Implants Res. 2019 Jun;30(6):505-514. doi: 10.1111/clr.13435. Epub 2019 May 7.

Abstract

OBJECTIVES

The aim of this RCT was to compare the accuracy of implant placement between static and dynamic computer-assisted implant surgery (CAIS) systems in single tooth space.

MATERIALS AND METHODS

A total of 60 patients in need of a single implant were randomly assigned to two CAIS groups (Static n = 30, Dynamic n = 30) and implants were placed by one surgeon. Preoperative CBCT was transferred to implant planning software to plan the optimal implant position. Implants were placed using either stereolithographic guide template (Static CAIS) or implant navigation system (Dynamic CAIS). Postoperative CBCT was imported to implant planning software, and deviation analysis with the planned position was performed. Primary outcomes were the deviation measurements at implant platform, apex, and angle of placement. Secondary outcome was the distribution of the implant deviation into each 3D direction.

RESULTS

The mean deviation at implant platform and implant apex in the static CAIS group was 0.97 ± 0.44 mm and 1.28 ± 0.46 mm, while that in the dynamic CAIS group was 1.05 ± 0.44 mm and 1.29 ± 0.50 mm, respectively. The angular deviation in static and dynamic CAIS group was 2.84 ± 1.71 degrees and 3.06 ± 1.37 degrees. None of the above differences between the two groups reached statistical significance. The deviation of implants toward the mesial direction in dynamic CAIS group was significantly higher than that of the static CAIS (p = 0.032).

CONCLUSIONS

Implant placement accuracy in single tooth space using dynamic CAIS appear to be the same to that of static CAIS. (Thai Clinical Trials Registry TCTR20180826001).

摘要

目的

本 RCT 的目的是比较静态和动态计算机辅助种植手术(CAIS)系统在单牙间隙中植入物放置的准确性。

材料与方法

共 60 名需要植入单颗种植体的患者随机分为两组 CAIS 组(静态 n=30,动态 n=30),由同一位外科医生进行种植体植入。术前 CBCT 转移到种植体规划软件中,规划最佳种植体位置。使用立体光刻引导模板(静态 CAIS)或种植体导航系统(动态 CAIS)植入种植体。将术后 CBCT 导入种植体规划软件,并与规划位置进行偏差分析。主要结果是种植体平台、根尖和植入角度的偏差测量值。次要结果是将种植体偏差分布到每个 3D 方向。

结果

静态 CAIS 组种植体平台和根尖的平均偏差为 0.97±0.44mm 和 1.28±0.46mm,而动态 CAIS 组分别为 1.05±0.44mm 和 1.29±0.50mm。静态和动态 CAIS 组的角度偏差分别为 2.84±1.71 度和 3.06±1.37 度。两组间无统计学差异。动态 CAIS 组种植体向近中方向的偏差明显高于静态 CAIS 组(p=0.032)。

结论

在单牙间隙中使用动态 CAIS 进行种植体放置的准确性似乎与静态 CAIS 相同。(泰国临床试验注册中心 TCTR20180826001)。