Abstract

Quantitation of kappa and lambda light chains was investigated as an alternative to immunoelectrophoresis or immunofixation in the analysis of sera for abnormal immunoglobulins. Normal values for the ratios of total immunoglobulins to total light chains, and for total kappa chains to total lambda chains, were established in 104 control sera and were 1.070 +/- 0.074 and 1.770 +/- 0.337, respectively. Protein electrophoresis plus quantitation of immunoglobulin heavy and light chains provided sufficient data for the analysis of 79% of apparent normal sera, 76% of apparent abnormal sera which did not have monoclonal components, 73% of abnormal sera which contained monoclonal components, and 53% of pediatric sera. However, this protocol failed to detect monoclonal components known to be present in two sera. These data indicate that this analytic approach cannot replace the subjective analysis of sera by immunoelectrophoresis or immunofixation.

摘要

在分析血清中的异常免疫球蛋白时,研究了κ和λ轻链的定量分析方法,作为免疫电泳或免疫固定的替代方法。在104份对照血清中确定了总免疫球蛋白与总轻链的比率以及总κ链与总λ链的比率的正常值,分别为1.070±0.074和1.770±0.337。蛋白质电泳加上免疫球蛋白重链和轻链的定量分析为79%的表观正常血清、76%的无单克隆成分的表观异常血清、73%的含有单克隆成分的异常血清以及53%的儿科血清提供了足够的数据用于分析。然而,该方案未能检测出已知存在于两份血清中的单克隆成分。这些数据表明,这种分析方法不能替代免疫电泳或免疫固定对血清进行的主观分析。