Suppr超能文献

叶酸的高压液相色谱测定法:一项协作研究。

High-pressure liquid chromatographic assay of folic acid: a collaborative study.

作者信息

McSharry W O, Mahn F P

出版信息

J Pharm Sci. 1979 Feb;68(2):241-3. doi: 10.1002/jps.2600680233.

Abstract

A collaborative study of the USP high-pressure liquid chromatographic assay for folic acid was performed. Two samples were analyzed in duplicate by 14 participating laboratories. Relative standard deviations for a single determination (RSDS) ranged from +/-0.40 to +/-2.39%. Based on an analysis of variance, it was concluded that the method of peak measurement was a major determinant of reproducibility and that graphical measurement was associated with a high standard deviation. Adequate resolution was obtained using a variety of columns and operating conditions. The interlaboratory RSDS was +/-1.8%.

摘要

开展了一项关于美国药典(USP)叶酸高效液相色谱测定法的协作研究。14个参与实验室对两个样品进行了双份分析。单次测定的相对标准偏差(RSDS)范围为±0.40%至±2.39%。基于方差分析得出结论,峰测量方法是重现性的主要决定因素,并且图形测量与高标准差相关。使用各种色谱柱和操作条件获得了足够的分离度。实验室间RSDS为±1.8%。

相似文献

3
Chromatographic assays for folic acid.
J Pharm Sci. 1977 Aug;66(8):1112-6. doi: 10.1002/jps.2600660815.
7
[Intake of folic acid in the total daily diet--effect of food preparation on its folic acid content].
Z Lebensm Unters Forsch. 1995 Mar;200(3):209-12. doi: 10.1007/BF01190496.
8
The application of tetrazolium bioautography to the identification of folic acid derivatives.
J Clin Pathol. 1970 Jul;23(5):411-3. doi: 10.1136/jcp.23.5.411.

文献AI研究员