Suppr超能文献

采用具有成本效益的流动注射系统,配备内部非接触式电导检测器和 LED 比色计,可同时直接测定人尿液中的尿素和肌酐。

Simultaneous and direct determination of urea and creatinine in human urine using a cost-effective flow injection system equipped with in-house contactless conductivity detector and LED colorimeter.

机构信息

Department of Chemistry, Faculty of Science, Silpakorn University, Nakhon Pathom, 73000, Thailand; Flow Innovation-Research for Science and Technology Laboratory (FIRST Labs.), Thailand.

Flow Innovation-Research for Science and Technology Laboratory (FIRST Labs.), Thailand; Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Bangkok, 10400, Thailand.

出版信息

Anal Chim Acta. 2019 Sep 27;1073:54-61. doi: 10.1016/j.aca.2019.05.003. Epub 2019 May 6.

Abstract

This work presents a cost-effective and simple flow injection analysis (FIA) system for simultaneous and direct determination of urea and creatinine in human urine. The FIA system comprises two in-house detectors, a contactless conductivity detector and a light emitting diode (LED) detector. The contactless detector was built as a flow-through detection cell with axial electrodes, commonly known as capacitively coupled contactless conductivity detector (C4D) and the diode detector was fabricated based on the concept of paired emitter detector diodes (PEDD). With appropriate dilution of urine, the sample is directly injected into a stream of glycine-NaOH buffer pH 8.8 (the gas donor stream) and is carried by the carrier through a urease minicolumn for on-line enzymatic hydrolysis. The generated NH diffuses from the carrier stream through a porous polytetrafluoroethylene (PTFE) membrane into a stream of deionized water (the acceptor stream) leading to an increase in the signal at the C4D due to the NH dissolution in the water. In this system, creatinine is determined based on the Jaffé reaction by merging a stream of alkaline picrate with the gas donor stream. The change in color is detected using the PEDD equipped with two green LEDs. Under the optimum condition, the linear range of urea and creatinine were 30-240 mg L and 10-500 mg L, with limits of detection of 9.0 mg L and 0.9 mg L, respectively. The proposed system provides satisfactorily good precision (RSD < 3%), with sample throughput of 31 sample h for the two analytes. The FIA system tolerates potential interference commonly found in human urine. The system was successfully applied and validated with selected reference methods.

摘要

本工作提出了一种经济高效且简单的流动注射分析(FIA)系统,用于同时直接测定人尿中的尿素和肌酐。FIA 系统由两个内部检测器组成,即非接触式电导检测器和发光二极管(LED)检测器。非接触式检测器构建为带有轴向电极的流通池,通常称为容性耦合非接触式电导检测器(C4D),而二极管检测器是基于对射式发射极二极管(PEDD)的概念制造的。通过适当稀释尿液,将样品直接注入甘氨酸-NaOH 缓冲液 pH 8.8(气体供体流)中,并由载流子携带通过脲酶微柱进行在线酶解。生成的 NH 通过多孔聚四氟乙烯(PTFE)膜从载流子流扩散到去离子水(接受流)中,导致 C4D 信号增加,这是由于 NH 在水中的溶解。在该系统中,肌酐是基于 Jaffé 反应通过将碱性苦味酸盐流与气体供体流合并来测定的。颜色变化使用配备两个绿光 LED 的 PEDD 进行检测。在最佳条件下,尿素和肌酐的线性范围分别为 30-240mg/L 和 10-500mg/L,检测限分别为 9.0mg/L 和 0.9mg/L。该系统提供了令人满意的良好精密度(RSD<3%),两种分析物的样品通量为 31 个/小时。FIA 系统可耐受人尿中常见的潜在干扰。该系统已成功应用并通过选定的参考方法进行了验证。