Stanojcic Nick, O'Brart David P S, Maycock Nick, Hull Chistopher C
Department of Ophthalmology, St Thomas' Hospital, London, UK.
Department of Ophthalmology, Queen Alexandra Hospital, Portsmouth, UK.
BMJ Open Ophthalmol. 2019 Apr 1;4(1):e000266. doi: 10.1136/bmjophth-2018-000266. eCollection 2019.
To investigate the effect of intraocular lens (IOL) glistenings on visual performance and evaluate a new glistenings grading methodology.
Thirty-four patients (34 eyes) were recruited. Corrected distance visual acuity (CDVA), mesopic gap acuity (MGA), functional contrast sensitivity (FCS) and forward light scatter were measured (Advanced Vision and Optometric Tests, City Occupational, London, UK). The IOL centre was imaged and glistenings density graded by three observers using the Miyata scale and a new system. Inter-rater reliability, association between the two grading scales, and correlations between glistenings grades and visual performance parameters were evaluated.
The intraclass correlation coefficient between graders for the new grading system was 0.769 (95% Confidence Interval [CI] 0.636 to 0.868). There was a significant association between the Miyata scale and the new grading system for all graders (r=0.533-0.895, p≤0.001). There was no association between CDVA or MGA and glistenings grade (r=- 0.098, p=0.583 and r=0.171, p=0.359, respectively). There was no association between FCS at mesopic light levels and glistenings grade (r=-0.032, p=0.864), or the straylight parameter and glistenings grade (r=0.021, p=0.916). No association was found between the integrated straylight parameter and glistenings grade (r=0.078, p=0.701).
The new glistenings grading scale was highly reproducible. In this cohort, glistenings in the same hydrophobic acrylic IOL after cataract surgery were not associated with changes in visual function, as assessed by a series of tests not previously used in glistenings research.
研究人工晶状体(IOL)闪烁对视觉性能的影响,并评估一种新的闪烁分级方法。
招募了34例患者(34只眼)。测量矫正远视力(CDVA)、中视间隙视力(MGA)、功能性对比敏感度(FCS)和前向光散射(使用英国伦敦城市职业高级视觉和验光测试)。对IOL中心进行成像,由三名观察者使用宫田量表和一种新系统对闪烁密度进行分级。评估评分者间信度、两种分级量表之间的关联以及闪烁等级与视觉性能参数之间的相关性。
新分级系统评分者间的组内相关系数为0.769(95%置信区间[CI]为0.636至0.868)。对于所有评分者,宫田量表与新分级系统之间存在显著关联(r = 0.533 - 0.895,p≤0.001)。CDVA或MGA与闪烁等级之间无关联(r = -0.098,p = 0.583;r = 0.171,p = 0.359)。中视光水平下的FCS与闪烁等级之间无关联(r = -0.032,p = 0.86),杂散光参数与闪烁等级之间也无关联(r = 0.021,p = 0.916)。未发现综合杂散光参数与闪烁等级之间存在关联(r = 0.078,p = 0.701)。
新的闪烁分级量表具有高度可重复性。在该队列中,白内障手术后同一疏水丙烯酸IOL中的闪烁与视觉功能变化无关,这是通过一系列先前未用于闪烁研究的测试评估得出的。