OBJECTIVE

This study aimed to compare the physiological responses induced by the modified shuttle walk test (MSWT), the 6-minute walk test (6MWT), and the pediatric Glittre activities of daily living test for children (TGlittre-P) in healthy children.

METHOD

This was an analytical observational cross-sectional study. All subjects underwent an anthropometric evaluation, pulmonary function test, TGlittre-P, 6MWT, and MSWT using a portable gas analyzer. Each test was conducted on the same day, and a maximum period of 15 days was considered for completion of the 3 days of data collection.

RESULTS

Overall, 24 subjects were included (mean age, 9.78 ± 1.27 years). The peak oxygen consumption (VO ) during the MSWT (1409.94 ± 285.13 mL/kg/min) was significantly higher than that during the TGlittre-P (982.19 ± 205.95 mL/kg/min) and 6MWT (982.85 ± 257.09 mL/kg/min) (P < .001 for both). There was no difference in VO  as well as most of the physiological variables between the 6MWT and TGlittre-P (P = .987). The MSWT VO correlated with the 6MWT VO (r = 0.67; P = .00) and the TGlittre-P VO (r = 0.43; P = .04). The VO values achieved in the 6MWT and TGlittre-P were also correlated (r = 0.68; P = .00). Unlike in the MSWT, in which the physiological measurements show an incremental response, the VO , heart rate, minute ventilation, and respiratory exchange ratio were stabilized in the TGlittre-P and 6MWT.

CONCLUSION

The TGlittre-P and 6MWT showed similar physiological responses and required less metabolic, respiratory, and cardiovascular overload than the MSWT. The performance measures and VO values obtained in the three tests were correlated.

摘要

目的

本研究旨在比较改良 shuttle 步行测试(MSWT)、6 分钟步行测试(6MWT)和小儿日常生活活动 Glittre 测试(TGlittre-P)在健康儿童中引起的生理反应。

方法

这是一项分析性观察性横断面研究。所有受试者均接受了人体测量评估、肺功能测试、TGlittre-P、6MWT 和使用便携式气体分析仪进行的 MSWT。每项测试均在同一天进行,完成 3 天的数据采集最多考虑 15 天。

结果

共有 24 名受试者入组(平均年龄 9.78±1.27 岁)。MSWT 时的峰值摄氧量(VO )(1409.94±285.13 mL/kg/min)明显高于 TGlittre-P(982.19±205.95 mL/kg/min)和 6MWT(982.85±257.09 mL/kg/min)(P<0.001 均)。6MWT 和 TGlittre-P 之间 VO 以及大多数生理变量无差异(P=0.987)。MSWT 的 VO 与 6MWT 的 VO 相关(r=0.67;P=0.00)和 TGlittre-P 的 VO (r=0.43;P=0.04)。6MWT 和 TGlittre-P 中获得的 VO 值也相关(r=0.68;P=0.00)。与 MSWT 不同,在 MSWT 中,生理测量显示出递增反应,而在 TGlittre-P 和 6MWT 中,VO 、心率、分钟通气量和呼吸交换率则稳定下来。

结论

TGlittre-P 和 6MWT 显示出相似的生理反应,并且比 MSWT 所需的代谢、呼吸和心血管过载更少。三项测试中的表现测量和 VO 值相关。