De Brux J L, Pernes J M, Grenier P h
Department of Cardiovascular Surgery, Hôpital Bichat, Paris, France.
Surg Radiol Anat. 1987;9(4):303-14. doi: 10.1007/BF02105302.
The authors present a correlation study between the anatomy of the heart and its appearance with magnetic resonance imaging (MRI) and ultrasonography (US). Six hearts were studied by MR, then sliced along the same planes. The results are presented and compared with the data obtained in volunteers by MRI and ultrasonography. The correlation between the MRI of isolated hearts and their anatomic slices is excellent, the thinnest anatomic details are reproduced. The use of double oblique slices provides incidences similar to those of ultrasonography. The same incidences can be obtained in vivo. The morphologic study of the heart by these imaging techniques is thus very precise, as well as the study of cardiac volumes.
作者展示了一项关于心脏解剖结构与其在磁共振成像(MRI)和超声检查(US)下外观的相关性研究。对六颗心脏进行了磁共振成像研究,然后沿相同平面切片。展示了研究结果,并与通过MRI和超声检查在志愿者身上获得的数据进行了比较。离体心脏的MRI与解剖切片之间的相关性极佳,最细微的解剖细节都能再现。使用双斜位切片得到的发生率与超声检查相似。在活体中也能获得相同的发生率。因此,通过这些成像技术对心脏进行的形态学研究以及心脏容积的研究都非常精确。