The role of contrast-enhanced spectral mammography in the evaluation of the postoperative breast cancer.

机构信息

Department of Radiology, Women's Imaging Unit, National Cancer Institute, Cairo University, Cairo, Egypt.

Department of Radiology, Women's Imaging Unit, Kasr ElAiny Hospital, Cairo University, Cairo, Egypt.

出版信息

Clin Radiol. 2019 Oct;74(10):771-781. doi: 10.1016/j.crad.2019.06.002. Epub 2019 Jul 6.

Abstract

AIM

To assess the utility of contrast-enhanced spectral mammography (CESM) to detect malignancy in the postoperative breast of cancer patients.

MATERIALS AND METHODS

The study was a prospective analysis of 76 women following operations for breast cancer. CESM was performed with low (22-33 kVp) and high (44-49 kVp) energy exposures after intravenous injection of contrast agent. Breast abnormalities were evaluated regarding the presence, morphology, and pattern of contrast medium uptake. The reference standard was histopathology of the Tru-Cut biopsy or surgical biopsy in cases where malignancy was suspected and absence of abnormality at follow-up sessions in benign cases.

RESULTS

Seventy cases were eligible for data analysis, and malignancy was detected in 48.6% (n=34/70). Enhancement at the operative bed was observed in 40 (57.14%) lesions. At traditional mammography, the diagnosis was false negative in 17/70 and false positive in 28/70 lesions, and presented a low sensitivity of 50%, a very low specificity of 22%, a positive predictive value of 37.7%, a negative predicative value of 32%, and an accuracy of 35.7%. CESM enhanced the performance of mammography and produced a sensitivity of 91.17%, a specificity of 75%, a positive predictive value of 77.5%, a negative predictive value of 90%, and an accuracy of 82.85%.

CONCLUSION

CESM is a credible technique that could be used in conjunction with the traditional mammogram to screen for cancer in the postoperative breast.

摘要

目的

评估对比增强光谱乳腺摄影术(CESM)在检测乳腺癌术后乳房恶性肿瘤中的应用价值。

材料与方法

这是一项对 76 例乳腺癌术后患者的前瞻性分析研究。在静脉注射造影剂后,采用低能(22-33 kVp)和高能(44-49 kVp)进行 CESM。根据造影剂摄取的存在、形态和模式评估乳腺异常。参考标准是恶性病变怀疑时的 tru-cut 活检或手术活检的组织病理学,良性病例的随访无异常。

结果

70 例病例符合数据分析条件,48.6%(n=34/70)检测到恶性肿瘤。40 个病变(57.14%)在手术床处有增强。在传统乳腺摄影中,70 个病变中有 17 个(17/70)为假阴性,28 个(28/70)为假阳性,其灵敏度为 50%,特异性为 22%,阳性预测值为 37.7%,阴性预测值为 32%,准确率为 35.7%。CESM 增强了乳腺摄影的性能,其灵敏度为 91.17%,特异性为 75%,阳性预测值为 77.5%,阴性预测值为 90%,准确率为 82.85%。

结论

CESM 是一种可靠的技术,可与传统乳腺 X 线摄影联合用于筛查乳腺癌术后乳房的癌症。