Abstract

OBJECTIVES

Programming the cochlear implant's speech processor with subjective methods in young, uncooperative children is difficult. Since young children cannot provide adequate feedback to the clinician, objective methods which do not require patient's response were often used. Electrical Stapedius Reflex Test is one of the most common procedures used. The goal of this study was to investigate the relationship between electricalstapedius reflex thresholds and behaviorally most comfortable levels in experienced cochlear implant users.

MATERIALS AND METHODS

The patients implanted with two brands of cochlear implants were compared in terms of electrical stapedius reflex thresholds versus most comfortable levels. Speech tests results were also compared between the two groups. 46 cochlear implanted patients who had at least 1 year of cochlear implant experience were included in the study. 28 patients were implanted with Nucleus, 18 patients with Med-El devices.

RESULTS

Moderate correlations were obtained between Electrical Stapedius Reflex (ESR) thresholds and C levels in Nucleus users; higher correlations were obtained for Med-El patients. ESR thresholds were present at higher levels than MCL/C levels in both Nucleus and Med-El users. No significant difference was obtained between the two groups in terms of speech tests.

CONCLUSION

ESR test can be very informative for programming young and uncooperative patients.

摘要

目的

对于年幼、不配合的儿童,使用主观方法来为人工耳蜗的言语处理器编程是很困难的。由于年幼的儿童无法向临床医生提供充分的反馈,因此通常会使用不需要患者响应的客观方法。电镫骨肌反射测试是最常用的程序之一。本研究的目的是探讨在有经验的人工耳蜗使用者中,电镫骨肌反射阈值与行为上最舒适水平之间的关系。

材料与方法

比较了植入两种人工耳蜗品牌的患者的电镫骨肌反射阈值与最舒适水平之间的关系。还比较了两组患者的言语测试结果。研究纳入了 46 名至少有 1 年人工耳蜗植入经验的人工耳蜗植入患者。28 名患者植入了 Nucleus 装置,18 名患者植入了 Med-El 装置。

结果

在 Nucleus 用户中,电镫骨肌反射(ESR)阈值与 C 级之间存在中度相关性;而在 Med-El 患者中,相关性更高。在 Nucleus 和 Med-El 用户中,ESR 阈值都高于 MCL/C 水平。两组患者在言语测试方面无显著差异。

结论

ESR 测试对于为年幼且不配合的患者编程非常有用。