Suppr超能文献

大直径陶瓷-陶瓷头在初次全髋关节置换术中的应用:一项多中心研究的平均 3 年随访结果。

Large head ceramic-on-ceramic bearing in primary total hip arthroplasty: average 3-year follow-up of a multicentre study.

机构信息

Hôpital Maisonneuve Rosemont, University of Montreal affiliated hospital, Montreal, Canada.

Turku University Hospital, Turku, Finland.

出版信息

Hip Int. 2020 Nov;30(6):711-717. doi: 10.1177/1120700019863376. Epub 2019 Jul 11.

Abstract

BACKGROUND

Surgeons are increasingly using larger femoral head sizes in total hip arthroplasty (THA) to improve stability and reduce the rate of dislocation, 1 of the leading causes of revision surgery. Large ceramic head sizes up to 48 mm can now be used with monoblock acetabular components. National registries have shown promising results at short-term with large diameter ceramic-on-ceramic THA, with very low revision rates.This study reports on the average 3-year follow up of a press-fit monoblock large diameter acetabular shell with a pre-assembled ceramic liner, with emphasis on the radiographic outcome, complications related to the implantation of the cup, and the patient's clinical outcome.

METHODS

170 hips in 169 patients were reviewed at an average 38 ± 5.8 months following surgery.

RESULTS

The radiographic review revealed no acetabular cup loosening, no osteolysis and no cup migration. 1 acetabular cup was revised for malposition. The patient clinical outcome and the satisfaction rate were excellent. At 3 years, 7.1% of patients complained of groin pain and 3.5% spontaneously reported hip joint generated noise. 1 patient sustained a non-recurrent traumatic hip dislocation 2 years post surgery.

CONCLUSIONS

New technology should be introduced cautiously on the market. This is especially true for the large diameter ceramic monoblock acetabular component used in this study since it involves a new acetabular component design. At short term, we have not identified new modes of failure with this implant. Longer follow-up is still needed to assess the safety of large ceramic bearing in THA.

摘要

背景

外科医生在全髋关节置换术(THA)中越来越多地使用更大的股骨头尺寸,以提高稳定性并降低脱位率,脱位是翻修手术的主要原因之一。现在可以使用最大直径为 48mm 的大型陶瓷头与整体式髋臼组件配合使用。国家注册中心显示,大直径陶瓷对陶瓷 THA 的短期结果很有希望,翻修率非常低。本研究报告了使用预组装陶瓷衬里的压配合式整体式大直径髋臼壳的平均 3 年随访结果,重点介绍了影像学结果、与植入杯相关的并发症以及患者的临床结果。

方法

术后平均 38±5.8 个月对 169 名患者的 170 髋进行了回顾。

结果

影像学检查显示髋臼杯无松动、无骨溶解和无杯移位。1 个髋臼杯因位置不正而进行了翻修。患者的临床结果和满意度均为优秀。3 年后,7.1%的患者抱怨腹股沟疼痛,3.5%的患者自发性报告髋关节产生噪音。1 名患者在术后 2 年内发生非复发性创伤性髋关节脱位。

结论

新技术应谨慎引入市场。对于本研究中使用的大直径陶瓷整体式髋臼组件尤其如此,因为它涉及到一种新的髋臼组件设计。在短期内,我们没有发现这种植入物有新的失效模式。仍需要更长时间的随访来评估大陶瓷轴承在 THA 中的安全性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验