Surgeons are increasingly using larger femoral head sizes in total hip arthroplasty (THA) to improve stability and reduce the rate of dislocation, 1 of the leading causes of revision surgery. Large ceramic head sizes up to 48 mm can now be used with monoblock acetabular components. National registries have shown promising results at short-term with large diameter ceramic-on-ceramic THA, with very low revision rates.This study reports on the average 3-year follow up of a press-fit monoblock large diameter acetabular shell with a pre-assembled ceramic liner, with emphasis on the radiographic outcome, complications related to the implantation of the cup, and the patient's clinical outcome.
170 hips in 169 patients were reviewed at an average 38 ± 5.8 months following surgery.
The radiographic review revealed no acetabular cup loosening, no osteolysis and no cup migration. 1 acetabular cup was revised for malposition. The patient clinical outcome and the satisfaction rate were excellent. At 3 years, 7.1% of patients complained of groin pain and 3.5% spontaneously reported hip joint generated noise. 1 patient sustained a non-recurrent traumatic hip dislocation 2 years post surgery.
New technology should be introduced cautiously on the market. This is especially true for the large diameter ceramic monoblock acetabular component used in this study since it involves a new acetabular component design. At short term, we have not identified new modes of failure with this implant. Longer follow-up is still needed to assess the safety of large ceramic bearing in THA.
外科医生在全髋关节置换术(THA)中越来越多地使用更大的股骨头尺寸,以提高稳定性并降低脱位率,脱位是翻修手术的主要原因之一。现在可以使用最大直径为 48mm 的大型陶瓷头与整体式髋臼组件配合使用。国家注册中心显示,大直径陶瓷对陶瓷 THA 的短期结果很有希望,翻修率非常低。本研究报告了使用预组装陶瓷衬里的压配合式整体式大直径髋臼壳的平均 3 年随访结果,重点介绍了影像学结果、与植入杯相关的并发症以及患者的临床结果。
术后平均 38±5.8 个月对 169 名患者的 170 髋进行了回顾。
影像学检查显示髋臼杯无松动、无骨溶解和无杯移位。1 个髋臼杯因位置不正而进行了翻修。患者的临床结果和满意度均为优秀。3 年后,7.1%的患者抱怨腹股沟疼痛,3.5%的患者自发性报告髋关节产生噪音。1 名患者在术后 2 年内发生非复发性创伤性髋关节脱位。
新技术应谨慎引入市场。对于本研究中使用的大直径陶瓷整体式髋臼组件尤其如此,因为它涉及到一种新的髋臼组件设计。在短期内,我们没有发现这种植入物有新的失效模式。仍需要更长时间的随访来评估大陶瓷轴承在 THA 中的安全性。