Suppr超能文献

陶瓷对陶瓷全髋关节置换术与大直径股骨头:系统评价。

Ceramic-on-Ceramic Total Hip Arthroplasty with Large Diameter Heads: A Systematic Review.

机构信息

Ortopedia-Traumatologia e Chirurgia Protesica e dei Reimpianti d'anca e di Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy,

Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy.

出版信息

Med Princ Pract. 2021;30(1):29-36. doi: 10.1159/000508982. Epub 2020 Aug 5.

Abstract

Ceramic-on-ceramic (COC) total hip arthroplasties (THAs) with large heads (>36 mm) were introduced to reduce dislocation rates and restore the hip anatomy as closely as possible to the native one. To date, the literature is scarce and fragmented; a review is desirable to point out the outcomes and the possible specific complications (noise, groin pain, and taperosis). A systematic review about large-diameter COC THAs was conducted according to the PRISMA guidelines. The PubMed and Cochrane databases were searched using the terms "large", "big", "head", "hip", and "ceramic." The methodological quality of the papers was assessed using the MINORS (Methodological Index for Nonrandomized Studies) score. Seven papers (level of evidence: 5 case series and 2 case-control studies) met the inclusion criteria. Clinical outcomes were excellent in >90% of the patients. Groin pain was reported in only 1 article (7%). Radiological outcomes were positive. Minimal revision rates (<2%) were reported at short- to mid-term follow-ups. Dislocation rates were usually <1%. No bearing surfaces failed. No case of trunnionitis was reported. Noise occurred in up to 30% of the patients, mostly squeaking. The noise did not influence clinical outcomes or patients' satisfaction. Noise was inconstantly associated with component positioning, younger age, high articular excursions, and larger sizes. Large-diameter heads in COC THAs (≥40 mm) showed promising clinical and radiological outcomes with minimal revision rates. Noise is a cause of concern and should be carefully evaluated at longer follow-ups and in larger, prospective, and specifically designed case series.

摘要

陶瓷对陶瓷(COC)全髋关节置换术(THA)采用大直径头(>36mm),以降低脱位率并尽可能接近地恢复髋关节解剖结构。迄今为止,相关文献有限且分散,需要进行综述以指出其结果和可能的特定并发症(如噪音、腹股沟疼痛和锥度)。根据 PRISMA 指南,对大直径 COC-THA 进行了系统评价。使用“大”、“大”、“头”、“髋”和“陶瓷”等术语在 PubMed 和 Cochrane 数据库中进行检索。使用 MINORS(非随机研究方法指数)评分评估论文的方法学质量。符合纳入标准的有 7 篇论文(证据水平:5 篇病例系列和 2 篇病例对照研究)。>90%的患者临床结果优秀。仅 1 篇文章(7%)报道了腹股沟疼痛。影像学结果为阳性。在短期至中期随访中,报告的最小翻修率(<2%)。脱位率通常<1%。无轴承面失效。未报告臼杯炎病例。高达 30%的患者出现噪音,主要是吱吱声。噪音并未影响临床结果或患者满意度。噪音与组件位置、年龄较小、关节活动度较大和尺寸较大等因素有关,但不恒定。COC-THA 中采用大直径头(≥40mm)显示出有前途的临床和影像学结果,最小翻修率较低。噪音是一个令人关注的问题,应在更长的随访时间内,在更大的、前瞻性的和专门设计的病例系列中进行仔细评估。

相似文献

1
Ceramic-on-Ceramic Total Hip Arthroplasty with Large Diameter Heads: A Systematic Review.
Med Princ Pract. 2021;30(1):29-36. doi: 10.1159/000508982. Epub 2020 Aug 5.
2
Excellent results of large-diameter ceramic-on-ceramic bearings in total hip arthroplasty: Is Squeaking Related to Head Size.
Bone Joint J. 2018 Nov;100-B(11):1434-1441. doi: 10.1302/0301-620X.100B11.BJJ-2018-0532.R1.
3
Do alumina matrix composite bearings decrease hip noises and bearing fractures at a minimum of 5 years after THA?
Clin Orthop Relat Res. 2015 Dec;473(12):3796-802. doi: 10.1007/s11999-015-4428-1.
4
Do the Reasons for Ceramic-on-ceramic Revisions Differ From Other Bearings in Total Hip Arthroplasty?
Clin Orthop Relat Res. 2016 Oct;474(10):2190-9. doi: 10.1007/s11999-016-4917-x.
6
Squeaking and other noises in patients with ceramic-on-ceramic total hip arthroplasty.
Hip Int. 2020 Jul;30(4):438-445. doi: 10.1177/1120700019864233. Epub 2019 Jul 21.
7
Could larger diameter of 4th generation ceramic bearing decrease the rate of dislocation after THA?
J Orthop Sci. 2016 May;21(3):327-31. doi: 10.1016/j.jos.2016.01.002. Epub 2016 Feb 11.
9
Midterm outcome of fourth-generation ceramic-on-ceramic bearing surfaces in revision total hip arthroplasty.
J Orthop Surg (Hong Kong). 2018 May-Aug;26(2):2309499018783913. doi: 10.1177/2309499018783913.

引用本文的文献

1
Predictors of mid-term outcomes in 334 developmental dysplasia hips treated with total hip arthroplasty.
BMC Musculoskelet Disord. 2025 Aug 7;26(1):762. doi: 10.1186/s12891-025-09041-9.
2
Factors Associated With Complications in 176 Crowe IV Hips Treated With Total Hip Arthroplasty.
Orthop Surg. 2025 Aug;17(8):2397-2404. doi: 10.1111/os.70120. Epub 2025 Jul 18.
5
Head size in Delta ceramic-on-ceramic total hip arthroplasty: a comparative registry study.
Arch Orthop Trauma Surg. 2024 Sep;144(9):4163-4170. doi: 10.1007/s00402-024-05504-1. Epub 2024 Sep 3.
7
8
Monobloc press-fit cups with large-diameter bearings are safe in revision total hip arthroplasty.
Orthop Rev (Pavia). 2022 Nov 3;14(4):38926. doi: 10.52965/001c.38926. eCollection 2022.
9
Fourth-Generation Ceramic-on-Ceramic THA in Patients with Ankylosing Spondylitis: A Minimum 10-Year Follow-Up.
Orthop Surg. 2022 May;14(5):860-867. doi: 10.1111/os.13259. Epub 2022 Apr 18.
10
Personalized Hip Joint Replacement with Large Diameter Head: Current Concepts.
J Clin Med. 2022 Mar 30;11(7):1918. doi: 10.3390/jcm11071918.

本文引用的文献

1
No radiological and biological sign of trunnionosis with Large Diameter Head Ceramic Bearing Total Hip Arthroplasty after 5 years.
Orthop Traumatol Surg Res. 2021 Feb;107(1):102543. doi: 10.1016/j.otsr.2019.12.015. Epub 2020 Apr 7.
2
Dislocation after total hip arthroplasty: does head size really matter?
Hip Int. 2021 May;31(3):320-327. doi: 10.1177/1120700019898404. Epub 2020 Jan 8.
4
Large head ceramic-on-ceramic bearing in primary total hip arthroplasty: average 3-year follow-up of a multicentre study.
Hip Int. 2020 Nov;30(6):711-717. doi: 10.1177/1120700019863376. Epub 2019 Jul 11.
5
Excellent results of large-diameter ceramic-on-ceramic bearings in total hip arthroplasty: Is Squeaking Related to Head Size.
Bone Joint J. 2018 Nov;100-B(11):1434-1441. doi: 10.1302/0301-620X.100B11.BJJ-2018-0532.R1.
6
Head size in primary total hip arthroplasty.
EFORT Open Rev. 2018 May 21;3(5):225-231. doi: 10.1302/2058-5241.3.170061. eCollection 2018 May.
8
Effect of sleeved ceramic femoral heads on titanium ion release.
Hip Int. 2018 Mar;28(2):139-144. doi: 10.5301/hipint.5000543. Epub 2017 Oct 16.
9
Epidemiology of Dislocation Following Direct Anterior Total Hip Arthroplasty: A Minimum 5-Year Follow-Up Study.
J Arthroplasty. 2016 Dec;31(12):2886-2888. doi: 10.1016/j.arth.2016.05.042. Epub 2016 May 31.
10
Squeaking in large diameter ceramic-on-ceramic bearings in total hip arthroplasty.
J Arthroplasty. 2015 Feb;30(2):282-5. doi: 10.1016/j.arth.2014.09.010. Epub 2014 Sep 28.

文献AI研究员