An outer layer of pure silicone rubber (SR), i.e. SR without any plasticizer, ionophore, or lipophilic anion, was applied on top of a conventional poly(vinyl chloride) (PVC) based K-selective membrane in a solid-contact ion-selective electrode (SC-ISE). The influence of the outer SR coating on the analytical performance of the K-ISEs was studied. The presence of the SR coating did not affect the selectivity of the SC-ISE, indicating that the plasticizer, ionophore, and lipophilic anion are spontaneously distributed from the PVC-based membrane into the SR layer. This was confirmed by electrochemical impedance spectroscopy (EIS). Interestingly, the reproducibility of the standard potential of the conditioned SC-ISE was significantly improved from ± 35.3 mV to ± 3.5 mV simply by adding the SR coating on top of the plasticized PVC based K-selective membrane. Moreover, the adsorption of bovine serum albumin (BSA) was significantly reduced at the SR coated ion-selective membrane. Thus, the addition of a SR coating on a plasticized PVC ion-selective membrane seems to be a feasible method to improve the analytical performance and to reduce the biofouling of potentiometric ion sensors.

摘要

在传统的聚氯乙烯(PVC)基 K 选择性膜上施加了一层纯硅橡胶(SR)的外层,即不含任何增塑剂、离子载体或亲脂性阴离子的 SR。研究了外层 SR 涂层对 K-离子选择性电极(SC-ISE)分析性能的影响。SR 涂层的存在并不影响 SC-ISE 的选择性,这表明增塑剂、离子载体和亲脂性阴离子会自发地从 PVC 基膜分布到 SR 层中。这一点通过电化学阻抗谱(EIS)得到了证实。有趣的是,通过在增塑 PVC 基 K 选择性膜上施加 SR 涂层,条件化 SC-ISE 的标准电位的重现性从 ±35.3 mV 显著提高到 ±3.5 mV。此外,在 SR 涂层的离子选择性膜上,牛血清白蛋白(BSA)的吸附明显减少。因此,在增塑 PVC 离子选择性膜上添加 SR 涂层似乎是一种可行的方法,可以提高分析性能并减少电位离子传感器的生物污染。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验