Dular R, Kajioka R, Kasatiya S
Public Health Laboratory, Ontario Ministry of Health, Ottawa, Canada.
J Clin Microbiol. 1988 May;26(5):1068-9. doi: 10.1128/jcm.26.5.1068-1069.1988.
The Gen-Probe rapid diagnostic system was compared with a culture method for the detection of Mycoplasma pneumoniae in clinical specimens. Of 116 clinical specimens, 103 (88.8%) yielded identical results. The relative sensitivity and specificity of the probe were both 89%. Rapid turnaround time and its sensitivity and specificity indicate that the probe test is a practical method for the rapid diagnosis of M. pneumoniae infections.