科学文献中与连续血糖监测使用相关的皮肤问题的记录。

Documentation of Skin-Related Issues Associated with Continuous Glucose Monitoring Use in the Scientific Literature.

机构信息

Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany.

Dermatology and Allergology, Feldafing, Germany.

出版信息

Diabetes Technol Ther. 2019 Oct;21(10):538-545. doi: 10.1089/dia.2019.0171. Epub 2019 Jul 25.

Abstract

The average wear time of continuous glucose monitoring (CGM) systems steadily increased over the last years. Increased wear times are likely achieved by using adhesives with a longer adherence time, which may have a more pronounced effect on the skin than adhesives with shorter adherence time. In this project, a structured literature search was performed to assess how potential skin-related issues with CGM usage have been reported in scientific literature in the last 5 years. The literature search was performed with four search terms in the PubMed database. In sum, 279 articles were analyzed. Skin-related issues were mentioned in 19.0% of articles (53 out of 279). With respect to articles mentioning skin-related issues, CGM performance or efficacy was the study's main topic of most of these studies, whereas the minority used CGM as "add-on" to assess other objectives. There was a varying degree in how detailed skin-related issues were described and no uniform structured documentation was given. While some articles only described findings, other articles already documented final diagnoses, such as contact dermatitis. Furthermore, inconsistent wordings for comparable issues were used. The most frequent issues were pain, itching, erythema, bleeding, bruising, and allergic reactions. To draw possible conclusions about the occurrence of skin-related issues during CGM use, more reports about skin-related issues in scientific literature are needed. A more detailed and uniformly structured documentation, possibly facilitated by a generally accepted guideline for structured descriptions, of skin-related issues could be helpful to enable clear differentiations between the described skin reactions.

摘要

连续血糖监测 (CGM) 系统的平均佩戴时间在过去几年中稳步增加。通过使用具有更长黏附时间的黏合剂,可以实现更长的佩戴时间,这可能比具有较短黏附时间的黏合剂对皮肤产生更明显的影响。在这个项目中,进行了系统的文献检索,以评估在过去 5 年中,科学文献中如何报告 CGM 使用相关的潜在皮肤问题。文献检索在 PubMed 数据库中使用了四个搜索词进行。总共分析了 279 篇文章。在提到皮肤相关问题的文章中,有 19.0%(53 篇)提到了皮肤相关问题。在提到皮肤相关问题的文章中,CGM 性能或疗效是这些研究的主要主题,而少数研究将 CGM 用作“附加”来评估其他目标。描述皮肤相关问题的详细程度各不相同,没有统一的结构化文档。虽然有些文章仅描述了发现,而其他文章已经记录了最终诊断,如接触性皮炎。此外,对于可比问题使用了不一致的措辞。最常见的问题是疼痛、瘙痒、红斑、出血、瘀伤和过敏反应。为了对 CGM 使用过程中出现皮肤相关问题得出可能的结论,需要在科学文献中报告更多关于皮肤相关问题的报告。更详细和统一结构化的文档记录,可能通过普遍接受的结构化描述指南来促进,这可能有助于在描述的皮肤反应之间进行明确区分。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验