Suppr超能文献

含抗生素结合树脂的需氧血培养瓶在接触β-内酰胺类和氟喹诺酮类浓度后,从其中回收革兰氏阴性菌。

Recovery of Gram-Negative Bacteria from Aerobic Blood Culture Bottles Containing Antibiotic Binding Resins after Exposure to β-Lactam and Fluoroquinolone Concentrations.

机构信息

Center for Anti-Infective Research and Development, Hartford Hospital, Hartford, Connecticut, USA.

Center for Anti-Infective Research and Development, Hartford Hospital, Hartford, Connecticut, USA

出版信息

J Clin Microbiol. 2019 Sep 24;57(10). doi: 10.1128/JCM.00849-19. Print 2019 Oct.

Abstract

Blood culture bottles containing antibiotic binding resins are routinely used to minimize artificial sterilization in the presence of antibiotics. However, the resin binding kinetics can differ between antibiotics and concentrations. This study assessed the impact of clinically meaningful peak, midpoint, and trough concentrations of meropenem, imipenem, cefepime, cefazolin, levofloxacin, and piperacillin-tazobactam on the recovery of , , and from resin-containing BacT/Alert FA Plus and Bactec Aerobic/F blood culture bottles. -inoculated bottles alarmed positive in 4/20 (20%), 16/20 (80%), and 20/20 (100%) of those with peak, midpoint, and trough concentrations of antipseudomonal agents, respectively ( ≤ 0.001). was recovered from 8/24 (33%), 11/24 (46%), and 14/24 (58%) of bottles with peak, midpoint, and trough concentrations, respectively ( = 0.221). was recovered from 8/16 (50%) at all concentrations of the studied antibiotics ( = 1.0). BacT/Alert and Bactec bottles inoculated with antibiotics and had similar times to detection (TTD) ( = 0.352); however, antibiotic-containing BacT/Alert bottles had a shorter TTD compared with antibiotic-containing Bactec bottles for ( = 0.026) and ( ≤ 0.001). Pathogen recovery in BacT/Alert FA Plus and Bactec Aerobic/F blood culture bottles containing antibiotic binding resins was greatly reduced in the presence of antibiotics, especially at higher concentrations. These data support the practice of drawing blood cultures immediately before an antibiotic dose to maximize the chances of pathogen recovery.

摘要

血培养瓶中含有抗生素结合树脂,通常用于在存在抗生素的情况下最大限度地减少人工灭菌。然而,树脂结合动力学可能因抗生素和浓度而异。本研究评估了临床有意义的美罗培南、亚胺培南、头孢吡肟、头孢唑林、左氧氟沙星和哌拉西林他唑巴坦的峰值、中点和谷浓度对含树脂的 BacT/Alert FA Plus 和 Bactec 需氧/血培养瓶中 、 、 的回收的影响。含抗假单胞菌药物的峰值、中点和谷浓度的 -接种瓶分别在 4/20(20%)、16/20(80%)和 20/20(100%)的瓶中阳性报警( ≤ 0.001)。分别从含抗生素的 8/24(33%)、11/24(46%)和 14/24(58%)瓶中回收了 ( = 0.221)。所有研究抗生素浓度下均从 8/16(50%)瓶中回收了 ( = 1.0)。含抗生素的 BacT/Alert 和 Bactec 瓶的检测时间(TTD)相似( = 0.352);然而,与含抗生素的 Bactec 瓶相比,含抗生素的 BacT/Alert 瓶的 TTD 较短,用于 ( = 0.026)和 ( ≤ 0.001)。在含有抗生素结合树脂的 BacT/Alert FA Plus 和 Bactec Aerobic/F 血培养瓶中,抗生素的存在大大降低了病原体的回收,尤其是在较高浓度下。这些数据支持在给予抗生素前立即抽取血培养以最大限度提高病原体回收机会的做法。

相似文献

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验