Suppr超能文献

CD34+造血干细胞的流式细胞术计数:采用国际血液治疗与移植工程学会方案对单平台与双平台方法的比较

Flow cytometric enumeration of CD34+ hematopoietic stem cells: A comparison between single- versus dual-platform methodology using the International Society of Hematotherapy and Graft Engineering protocol.

作者信息

Murugesan Mohandoss, Nair Chandran K, Nayanar Sangeetha K, Pentapati Kalyana Chakravarthy

机构信息

Department of Transfusion Medicine, Malabar Cancer Centre, Thalassery, Kerala, India.

Department of Clinical Hematology, Malabar Cancer Centre, Thalassery, Kerala, India.

出版信息

Asian J Transfus Sci. 2019 Jan-Jun;13(1):43-46. doi: 10.4103/ajts.AJTS_83_18.

Abstract

BACKGROUND

Flow cytometric enumeration of CD34+ hematopoietic stem cells (HSC) is the reference point for undertaking apheresis and evaluation of adequacy for peripheral blood stem cell (PBSC) engraftment.

AIMS

To determine whether single platform correlates with dual platform methods in CD34+ enumeration using ISHAGE protocol.

METHODS

Retrospective analysis of CD34 Enumeration assays on both peripheral blood and PBSC product samples using Beckman Coulter FC500 Flow Cytometer. The t test and correlation study was used to study the difference between single and dual platform methods in CD34+ enumeration.

RESULTS

We present our data on 152 samples comprising 41 peripheral blood samples collected before apheresis procedure and 111 samples collected from PBSC product. We observed strong positive correlation between single and dual platform methods for CD34+ counts in peripheral blood sample ( = 0.92; < 0.001) and PBSC product sample ( = 0.85; < 0.001).

CONCLUSION

In our study, both single versus dual platform had similar results in CD34+ cell counts. The single platform provides rapid results with ease of procedure. Errors with dual platforms are relatively common with respect to denominator. We recommend to use mean of total leukocyte count from two different hematology analyzer to minimize variation in dual platform.

摘要

背景

流式细胞术计数CD34+造血干细胞(HSC)是进行单采术以及评估外周血干细胞(PBSC)植入充分性的参考标准。

目的

使用ISHAGE方案确定在CD34+计数中,单平台法与双平台法是否具有相关性。

方法

使用贝克曼库尔特FC500流式细胞仪对来自外周血和PBSC产品样本的CD34计数检测进行回顾性分析。采用t检验和相关性研究来分析单平台法与双平台法在CD34+计数方面的差异。

结果

我们展示了152份样本的数据,其中包括41份在单采术前采集的外周血样本和111份从PBSC产品中采集的样本。我们观察到在外周血样本(r = 0.92;P < 0.001)和PBSC产品样本(r = 0.85;P < 0.001)中,单平台法与双平台法在CD34+计数之间存在强正相关。

结论

在我们的研究中,单平台法与双平台法在CD34+细胞计数方面结果相似。单平台法操作简便,能快速得出结果。双平台法在分母方面相对容易出现误差。我们建议使用两台不同血液分析仪的总白细胞计数均值,以尽量减少双平台法中的差异。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8d5a/6580824/9f432f786ae0/AJTS-13-43-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验