基于 Exo III 辅助循环放大的比率型电化学生物传感器用于检测 CAG 三核苷酸重复序列。

Ratiometric electrochemical biosensor based on Exo III-Assisted recycling amplification for the detection of CAG trinucleotide repeats.

机构信息

Hubei Collaborative Innovation Center for Advanced Organic Chemical Materials & Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules, Hubei University, Youyi Road 368, Wuchang, Wuhan, Hubei, 430062, PR China.

Hubei Collaborative Innovation Center for Advanced Organic Chemical Materials & Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules, Hubei University, Youyi Road 368, Wuchang, Wuhan, Hubei, 430062, PR China.

出版信息

Biosens Bioelectron. 2019 Oct 1;142:111537. doi: 10.1016/j.bios.2019.111537. Epub 2019 Jul 25.

Abstract

Electrochemical detection of specific nucleic acid sequence remains a hot topic in current bioanalytical research. Here, a novel ratiometric electrochemical biosensor based on Exo III-assisted recycling amplification and graphene-modified electrode was fabricated for quantitative detection of trinucleotide repeat sequence d(CAG). The double-signals used are the hairpin DNAs labeled with ferrocene and methylene blue respectively as report DNAs, which can hybridize to target DNA. The hybridized DNA was digested by Exo III, resulting in the release of target and report fragments. The graphene-modified electrode can selectively adsorb the released report fragments to generate double electrochemical signals. The signal ratio (F/M) of ferrocene and methylene blue was used to determine the repeat length accurately: a linear relationship was found between F/M and numbers of repeats (n), F/M = 0.061 n + 1.97, with a correlation coefficient of 0.992. Moreover, any electrochemical signal can be used to test repeat concentration with detection limit of 0.22 pM. Therefore, this novel ratiometric electrochemical biosensor provided a reliable and efficient method for the analysis of d(CAG) trinucleotide repeat and a potential simplified clinical tool for neurodegenerative diseases.

摘要

电化学检测特定的核酸序列仍然是当前生物分析研究的热门话题。在这里,我们构建了一种新型的基于 Exo III 辅助循环放大和石墨烯修饰电极的比率型电化学生物传感器,用于定量检测三核苷酸重复序列 d(CAG)。所使用的双信号是分别标记有二茂铁和亚甲基蓝的发夹 DNA 作为报告 DNA,它们可以与靶 DNA 杂交。杂交 DNA 被 Exo III 消化,导致目标和报告片段的释放。石墨烯修饰电极可以选择性地吸附释放的报告片段以产生双电化学信号。二茂铁和亚甲基蓝的信号比(F/M)用于准确地确定重复长度:F/M 与重复次数(n)之间存在线性关系,F/M=0.061 n+1.97,相关系数为 0.992。此外,任何电化学信号都可以用于测试重复浓度,检测限为 0.22 pM。因此,这种新型的比率型电化学生物传感器为分析 d(CAG)三核苷酸重复提供了一种可靠和高效的方法,并且可能成为神经退行性疾病的一种简化的临床工具。